TECHNICAL SPECIFICATIONS
- transmission frequency
- modulation
- power supply (lithium battery) 3 V
- power consumption during transmission
- operating temperature range
- relative humidity
- protection grade
- encoding type
- number of possible code combinations (128 bit)
- number of functions (channels)
- automatic shut down: after 5 sec. in stand-by
after 20 sec. during programming
ACTIVATION CODE
- Number of user codes (max 6 digits each)
- Number of available code combinations
Use
The SSB504/508 working together with a series S500
receiver allows the remote activation of electrical and
electronic devices that require high security such as:
alarm systems, automatic opening systems, access
control etc. and is best used in the command of
automatic gates and doors.
OVERALL DIMENSIONS
433,92 / 868,3 MHz
FM/FSK
model ZRA3.0-3.8-W
30mA
-10°...+55°C
<95%
IP 57
rolling code
2
128
4
The product conforms to the directive 99/05/CE
Attention! Old batteries must be disposed of according to the local
standards and regulations in force. For more information consult
500
the instructions supplied with the receiver. Conserve the instruc-
1 million
tions for later use.