- By pulling on the stirrer rod, you can pull the
ErgoFix adaptor [1-8] out of the machine spin-
dle. In this way, you can adjust fi ve different
working heights. One step is 2 cm. The maxi-
mum adjustment movement is 8 cm and the
end position is signalled by reaching the groove
[2-2] on the ErgoFix adapter.
- Then release the clamping ring of the ErgoFix
adapter [1-7] and check that the adapter [1-8]
is seated securely in the machine spindle.
Quick change function
Ensure that the adapter [1-8] remains
clean.
Do not lubricate the adaptor [1-8].
Only press the ErgoFix casing [1-7] when
the machine is not in operation.
The ErgoFix interface enables you to easily and
quickly remove the stirrer rod from the machine.
- Push the clamping ring of the ErgoFix adapter
[1-7] in the direction of the machine to move it
as far as it goes and hold it tight.
- By pulling on the stirrer rod, you can pull the
ErgoFix adaptor [1-8] completely out of the ma-
chine spindle.
Changing the stirrer
► Adapter ErgoFix [2-1] after worn-out of stirrer
rod can be reused.
Set the wrench [2-3] on the hexagon of the stirrer
endpiece [2-4] and turn to the left to screw the
stirrer rod out of the ErgoFix adapter [2-1].
6.6

Stirrer

To mix different material mixtures together, use
different PROTOOL stirrers: see the catalogue
NOTE
PJ Uni
For wall paints,
emulsion paints,
ready-made fi ller,
ready-mix plaster,
varnishes/glazes
RS
For wall paints,
emulsion paints,
pastes, varnishes
casting compounds,
bitumen, sludges
HS2
For tile adhesives,
joint sealant, adhe-
sive mortar, ready-mix
plaster, screed, fi llers,
levelling compounds
6.7

Mains connection

WARNING
There is a risk of accidents occurring if you
do not use the correct power supply.
The stirrer must only be operated with a single-
phase alternating current with a nominal voltage of
220–240 V/50–60 Hz. In the 2nd level, the machine
is protected against accidents caused by electrical
current in accordance with the standard EN 60 745-1
and it has built-in radio interference suppression in
accordance with the standard EN 55 014.
Before starting up the machine, check that the
specifi cations on the type plate correspond to the
actual voltage of the power supply.
If required, you can extend the fl exible power cable
as follows:
- Length 20 m, conductor cross-section
3×1.5 mm
2
- Length 50 m, conductor cross-section
3×2.5 mm
2
Only use extension cables that are suitable for
outside use and that are marked accordingly.
HS3R
For mortar, concrete,
cement and lime
plaster adhesive fi ller,
screed, quartz-fi lled
epoxy resin, thick
bitumen coating
HS3L
For gypsum plaster,
emulsion paints,
varnishes wall paints,
casting compounds
WS
For paints, varnishes,
wall paints, emulsion
paints, plasters, glues,
tile adhesives
CS
For balancing weights,
fi llers, sealants,
adhesives
13