Preparation; Technical Data - Sharpe Finex FX100 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FINEX HVLP AND CONVENTIONAL SPRAY GUNS
Service
WARNING
Follow Pressure Relief Procedure when you stop spraying
and before cleaning, checking, or servicing equipment. Read
warnings, page 2.

Preparation

1. Flush and clean gun before servicing. See page 3.
2. Follow Pressure Relief Procedure, page 1.
Air Cap, Nozzle, and Needle
1. Unscrew air cap (1). F
2. Trigger gun while you remove the nozzle (2) with gun
tool (27). See F
. 5.
IG
CAUTION
Trigger gun and use gun tool (27) whenever you tighten or
remove the nozzle (2) to avoid damage.
3. Remove fluid adjustment knob (20) and spring (19).
F
. 6.
IG
4. Pull needle (18) out the back of the gun.
2
27
YES
F
. 5
IG
20 19
18
F
. 6
IG
Air Valve and Needle Packings
1. Remove retaining ring (26), gaskets (24), pin (25) and
trigger (23). F
. 7.
IG
2. Remove packing nut (4) and packing (3).
3. Remove air valve shaft (8).
4. Remove fitting (17) with Allen wrench (FX100: 8 mm,
FX200/300: 9 mm).
5. Remove o-rings (13, 10) and holder (9) from
fitting (17).
6. Remove spring (16), piston (14), and o-ring (10).
7. Remove air valve seat (12) with o-ring (13)
and gasket (11).
8. Remove o-ring (10) and holder (9).
9. Replace parts as needed.
. 6.
IG
NO
2
1
10. Reassemble in reverse order. Lubricate needle and
o-rings. Tighten o-ring packing holders (9) until
smooth movement of the valve air shaft (8) and air
valve piston (14) is achieved. DO NOT over tighten
the o-ring packing holders (9) as a sluggish needle or
sticky trigger condition will result. Be sure to trigger
gun when installing nozzle (2).
30
29
6
1
2
5
4
3*
8
9* 10*
26*
24
24
25
15*
23
F
. 7
IG

Technical Data

Maximum Working Air Pres-
sure
Maximum HVLP Inbound Air
Pressure .
Fluid and Air Operating Tem-
perature Range
Weight
FX100
FX200
FX300
Air Inlet
Wetted Parts
Noise Data
FX100 Sound Pressure
Sound Power
FX200 Sound Pressure
Sound Power
FX300 Sound Pressure
Sound Power
Air Consumption
FX100
FX200
FX300
5
28
15*
27
11* 12
7
10* 9*
13* 10* 14 16*
13*
18
21
22
19*
20
TI5088B
100 psi
(0.7 MPa, 7 bar)
29 psi
(0.2 MPa, 2 bar)
32–109° F (0–43° C)
14 oz. (40 g)
24 oz. (68 g)
24 oz. (68 g)
1/4-18 npsm (R1/4-19) compound
thread
Aluminum, stainless steel, brass,
PTFE
64.08 dB(A)
73.97 dB(A)
79.01 dB(A)
88.91 dB(A)
72.98 dB(A)
82.88 dB(A)
4.9 cfm at 29 psi (200 kPa, 2 bar)
11.9 cfm at 41 psi (283 kPa, 2.8 bar)
11.4 cfm at 29 psi (200 kPa, 2 bar)