Remote Control Operation - PARMAZ ARD-12 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

NOTE
The air conditioner does not cool the room when operating as a dehumidifier.
When the appliance is used as a dehumidifier, the flexible pipe must not be connected.
For maximum dehumidification efficiency, leave the rear discharge attachment free to discharge directly into
the environment.
The dehumidification mode is recommended during autumn and winter.
lf used during summer, it is best to leave the flexible pipe attached so that the hot air is discharged towards
the outside rather than into the room.
During dehumidification, continuous drainage should be implemented (see the next chapter, "HOW TO ELIMINATE
CONDENSA TE").
4. VENTILATION MODE (FAN ONLY)
• Press the MODE button until the Fan icon appears.
• In this mode, the fan speed can be adjusted.
• The temperature cannot be adjusted.
Drain oullet
1.
Slide to open the cover according to the direction indicated
by the arrowhead.
2.
lnsert the batteries (CR2032/3V) into the remate control
and make sure the pales match.
3.
Put back the cover.
4.
Aim the remate control towards the receiver on the air­
conditioner.
5.
The remate control should be within 8 meters away from
HOW TO ELIMINATE CONDENSATE
Cooling & Heating (Pearl top)
This appliance automatically vaporises condensate in the cooling and heating mode.
Ensure that when the unit is operating in cooling and heating mode, the rubber caps
closing the drainage hales on the rear of the appliance are properly positioned.
When the air conditioner operates in cooling and heating mode, there is no need far
continuous condensate drainage; only in specific weather conditions with very high air
humidity levels may water deposit inside the unit. When the interna! container is full,
the display visualises message "P1" and the appliance stops functioning.
To empty the container, switch the air conditioner off and unplug it. Remove the cap
farm the rear drainage hole and direct it over a normal drain.
Ensure that the tube is not twisted or bent. The tube must slope downwards. Re-clase
the drainage hale with the cap and resume use of the air conditioner.
Dehumidification
WARNING!
When using the air conditioner in dehumidification mode, it is advisable to always
arrange far continuous drainage, so as to maximise dehumidification efficiency.
Connect one end of the PVC pipe provided to the rear discharge hale and place the
other end above a drain.

REMOTE CONTROL OPERATION

35

Publicité

Table des Matières
loading

Table des Matières