L .P . Gas Water Heater

4.8 Installing The Access Door

w
q
14 Attaching the Access Door with the Hinge Pin
Hinge Pin
q
Clip
w
1. Snap the hinge pin into the clip.
2. Slide the access door onto the hinge pin.
3. Slide the hinge pin into the access door, snapping it
into the clip at the same time.
I
To remove the hinge pin, support the access door
and apply force to the corner of the hinge pin.
4. Seal both corners with caulk.
I
It is recommended to apply caulk to the hinge pin
and the clip once the door installed. This will aid in
hinge pin retention.

4.9 Performing Leak Testing


WARNING: FIRE AND/OR EXPLOSION
HAZARD.
Do not use matches, candles, or other sources
of control when checking for gas leaks. Failure to
obey this warning could result in death or serious
injury.
EN
e
Access Door
e
I
Isolate the Water Heater from the gas supply piping
system before performing any pressure test equal to
or greater than 0.5 PSI (34 mbar).
1. Turn on the gas and check the Water Heater and all
of the connections for gas leaks using leak detection
solution.
2. Fill the water heater tank with water.
3. Check the tank and all water hose connections for leaks.

5 Operation


WARNING: BURN HAZARD, FIRE,
EXPLOSION, AND/OR CARBON MONOXIDE
HAZARD.
Keep the water heater area clear of combustible
cleaning materials, gasoline, and other flammable
vapors and liquids. Failure to obey this warning
could result in death or serious injury.

WARNING: FIRE AND/OR EXPLOSION
HAZARD. Failure to obey this warning could
result in death or serious injury:
• Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
• Should overheating occur, or the gas supply fail to
shut off, turn the operating switch to the OFF position
and remove the red wire from the left hand terminal of
the E.C.O. switch or turn the gas off at the L.P. tank.
• Use with L.P. gas only.
• Shut off gas appliances and pilot lights when
refueling.
• Turn gas off at the L.P. tank when the vehicle is in
motion. This disables all gas appliances and pilot
lights.
• Gas appliances must never be operated while the
vehicle is in motion. Unpredictable wind currents
may be created which could cause flame reversal in
the burner tub, which could result in fire damage.
The thermal cut off fuse could also be unnecessarily
activated resulting in a complete shutdown of the
water heater requiring replacement of the thermal cut
off.
Operation