Remedy of faults

Malfunction
The unit does not start up
Insufficient fountain height

Maintenance and cleaning

If necessary, clean the unit with clear water using a soft brush.
• Do not use aggressive cleaning agents or chemical solutions as they could attack
the housing or impair the function of the unit.
• Recommended cleaning agent for removing stubborn limescale deposits:
– Vinegar- and chlorine-free household cleaning agent.
• After cleaning, thoroughly rinse all parts in clean water.
Replacing the impeller unit
How to proceed:
FP 200/200i/450/450i/750/750i/1500/1500i:
 E
1. Pull off the filter housing.
2. Remove the pump lid.
– FP 200/200i/450/450i: Pull off the pump lid.
– FP 750/750i/1500/1500i: Unscrew the pump lid.
3. Pull the running unit out of the pump housing and replace the running unit.
4. Reassemble the pump in the reverse order.
FP 1000/1000i:
1. Pull off the filter housing.
2. Unscrew the locking ring.
3. Pull off the pump lid.
4. Pull the running unit out of the pump housing and replace the running unit.
5. Reassemble the pump in the reverse order.
20
Cause
No mains voltage
Running unit blocked
Flow regulator turned too far
Pump casing or impeller unit
soiled, hose blocked
Hose defective
Hose kinked
Impeller unit worn
Remedy
Check the mains voltage.
Clean
Set flow regulator
Clean
Replace
Route hose in a straight line
Replace impeller unit