SPECIFICATIONS
Model:
Max. feed volume
Water flow rate
Max. permissible pressure
Working pressure
Max. feed pressure
Max. feed temperature
Max. suction height
Dimensions
(L x W x H)
Weight
Motor protection
Due to our continuing program of research and development, the specifications herein are subject to change
without notice.
Specifications may differ from country to country.
Weight according to EPTA-Procedure 01/2003
Symbols
The following show the symbols used for the equip-
ment. Be sure that you understand their meaning before
use.
Read the instruction manual.
Take particular care and attention.
DOUBLE INSULATION
Only for EU countries
Do not dispose of electric equipment
together with household waste material! In
observance of the European Directive, on
Waste Electric and Electronic Equipment
and its implementation in accordance with
national law, electric equipment that have
reached the end of their life must be col-
lected separately and returned to an envi-
ronmentally compatible recycling facility.
Do not direct the jet at people including
yourself, animals, and live electrical
equipments.
High mode
Low mode
HW1200
7.0 l/min
5.5 l/min
12 MPa (120 bars)
10 MPa (100 bars)
-
292 mm x 358 mm x 830 mm
11.0 kg
Not suitable for connection to the potable
water mains.

Intended use

This tool is intended for cleaning stubborn dirt by using
water jet. This tool is intended for household use.

Power supply

The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated and can, therefore, also be used
from sockets without earth wire.
For public low-voltage distribution
systems of between 220 V and 250 V
Switching operations of electric apparatus cause voltage
fluctuations. The operation of this device under unfavor-
able mains conditions can have adverse effects to the
operation of other equipment. With a mains impedance
equal or less than 0.25 Ohms it can be presumed that
there will be no negative effects. The mains socket used
for this device must be protected with a fuse or protective
circuit breaker having slow tripping characteristics.
9 ENGLISH
HW1300
7.5 l/min
6.0 l/min
13 MPa (130 bars)
11 MPa (110 bars)
8 MPa (80 bars)
1 MPa (10 bars)
40 °C
1.0 m
12.7 kg
IPX5