Bosch Rexroth LTU350/1 Mode D'emploi page 21

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29
3 609 929 B47/2008-12 | LTU350/1
Display
The graphic LC display (Figure 2) enables a
display of the result values (torque, angle,
gradient, time) and error codes. Texts are
shown in 4 lines, each with 8 characters. The
display is permanently backlit (LED).
The contrast can be adjusted in the BS350
operating system, if necessary.
W
571.33
M
35.10
Fig. 2: LC display
Display
Table 1
Target function
Upper torque
Lower torque
Relative torque, upper
Relative torque, lower
Angle
Input
Time
Yield point
Gradient
OK
Actual value
T
TI
T&
TI&
A
IN
t
Yp
G
Bosch Rexroth AG
Table 2
Monitoring function
Torque
Relative torque
Torque max. value
Torque min. value
Torque average value
Torque range
Redundancy torque
Tightening from above
Tightening from below
Angle
Total angle
Redundancy angle
Gradient
Gradient average value GA
Time
Stick slip
Yield point
Table 3
Function
Actual value Displays
Total time
to
Table 4
Event
Marking
Remove start sig-
C(c)w
nal
System error
Fault
The inverse display shows:
– Error
– NOK.
21/84
Actual value
T
T&
T>
T<
TA
T[
TR
TCh
TCl
A
AO
AR
G
t
STS
Yp
Yes/No
Yes
0