2.5 - List of cables required

The cables required for connection of the various devices in a
standard system are listed in the cables list table.
ELECTRIC CABLE TECHNICAL SPECIFICATIONS
Power line
Flashing light, Courtesy light, ambient light sensor
Antenna
Electric lock
Transmitter photocells
Receiver photocells
Sensitive edge
Key-operated selector switch
Motor power supply line
Encoder power supply line
* If the power supply cable is more than 20 m long, it must be of
larger gauge (3x2.5mm2) and a safety grounding system must be
installed near the automation unit.

3 - PRELIMINARY CHECKS

Before installing this product, verify and check the following steps:
- Check that the gate or door are suitable for automation
- The weight and size of the gate or door must be within the maximum
permissible operating limits
- Check the presence and strength of the security mechanical stops
of the gate or door
- Check that the mounting area of the product is not subject to
flooding
- Conditions of high acidity or salinity or proximity to heat sources
could cause malfunction of the product
- Extreme weather conditions (for example the presence of snow,
ice, high temperature range, high temperatures) may increase the
friction and therefore the force required for the handling and initial
starting point may be higher than under normal conditions.
20
CONNECTION
The cables used must be suitable for the type of installation; for
example, an H03VV-F type cable is recommended for indoor
applications, while H07RN-F is suitable for outdoor applications.
CABLE
1 cable of 3 x 1.5 mm2
4 x 0.5 mm2**
1 RG58 type cable
1 cable of 2 x 1 mm2
1 cable of 2 x 0.5 mm2
1 cable of 4 x 0.5 mm2
1 cable of 2 x 0.5 mm2
1 cable of 4 x 0.5 mm2**
1 cable of 2 x 1.5 mm2
1 cable of 3 x 0.5 mm2
** Two cables of 2 x 0.5 mm2 can be used as an alternative
- Check that the manual operation of gate or door is smooth and
friction-free and there is no risk of derailment of the same
- Check that the gate or door are in equilibrium and stationary if left
in any position
- Check that the power line to supply the product is equipped with
proper grounding safety and protected by a magnetothermal and
differential security device
- Provide the power system with a disconnecting device with a gap
of contacts enabling full disconnection under the conditions dictated
by the overvoltage category III.
- Ensure that all materials used for the installation comply with
current regulations
MAXIMUM PERMITTED LIMIT
20 m *
20 m
20 m (< 5 m recommended)
10 m
20 m
20 m
20 m
20 m
10 m
10 m