Do not splash or spray water from a hose on the ice
machine. Doing so may cause an electrical shock,
which may result in severe injury or death.
•
This ice machine should not, under any circum-
stances, be installed to an un-grounded electrical
supply.
Electrical Connection
A grounded 115 volt, 15 amp dedicated circuit is required.
This product is factory equipped with a power supply
cord that has a three-pronged, grounded plug. It must be
plugged into a mating grounding type receptacle in ac-
cordance with the National Electrical Code and applicable
local codes and ordinances (see Figure 4). If the circuit
does not have a grounding type receptacle, it is the respon-
sibility and obligation of the customer to provide the proper
power supply. The third ground prong should not, under
any circumstances, be cut or removed.
be hazardous and cause deficient operation. The wall
receptacle should be located near the ice machine and
be a polarized type with adequate ground protection.
The ice machine must be installed to your local build-
ing codes and ordinances.
NOTE
Ground Fault Circuit Interrupters (GFCI) are prone to
nuisance tripping which will cause the ice machine to shut
down. GFCI's are generally not used on circuits, with pow-
ered equipment, that must run unattended for long periods
of time, unless required to meet local building codes and
ordinances.
INSTALLING THE DRAIN PLUMBING
Electrical Extension cords
should not be used. They can
Figure 4
Risk of electrical shock or personal injury could occur due
to moving components, if machine compartment access
cover is removed before unplugging the ice machine.
Drain Plumbing
Your ice machine requires drain plumbing. There are 2
variations of ice machines in regards to the installation of
the drain plumbing, without a drain pump (gravity drain),
and with a drain pump.
Gravity Drain, no drain pump.
Your ice machine requires a gravity drain (Figure 5) that re-
quires
⁄
inch outside diameter (O.D.) tubing from the back
5
8
of the ice machine to a plumbed connection to a sanitary
sewer. The gravity drain location for built-in ice machines
can be within the shaded area shown in Figure 7.
With a factory installed drain pump.
Your ice machine has a factory installed drain pump. The
discharge tubing is coiled up and attached to the back
of the ice machine. The
plumbed and connected to a sanitary sewer. Refer to
Figure 6. The maximum lift of the drain pump is 8 feet (2.44
meters) through the
⁄
3
8
Conversion of factory installed system to a
gravity drain system
Service kit 42248304 will be required if the ice machine is
converted to a gravity drain. Removal of the drain pump
without service kit 42248304 will prevent the ice machine
from continued ice production.
Optional Drain Pump.
An optional drain pump (Figure 6) is available if you have
purchased an ice machine without one and do not have ac-
cess to a gravity drain. Installation instructions are provided
with the optional drain pump. Contact Marvel customer
service for ordering.
Observe and follow all local codes when installing ice
machine.
This drain pump is designed to be installed in Marvel ice
machines only.
surrounding water damage and/or poor ice production.
5
⁄
inch I.D. tubing needs to be
3
8
inch I.D. tubing.
Failure to use an adequate
drainage system, will result in