HOMEOWNERS GUIDE
69-130ERVD-OWNERS 012716
511 McCormick Blvd.
General Info/Tech Support:
1 855. 247 4200
London, ON
Canada
Online:
N5W 4C8
www.lifebreath.com

Publicité

Table des Matières
loading

Sommaire des Matières pour Lifebreath PURE PERFORMANCE 130 ERV-D

  • Page 1 130 ERV-D HOMEOWNERS GUIDE 69-130ERVD-OWNERS 012716 511 McCormick Blvd. General Info/Tech Support: 1 855. 247 4200 London, ON Canada Online: N5W 4C8 www.lifebreath.com...
  • Page 2 Homeowner Information Dealer / Contractor Information Model___________________________________ Dealer_________________________________ Serial Number____________________________ Installer________________________________ Telephone/Contact_______________________ Installation Date_________________________ Register your ERV for warranty at www.lifebreath.com For any warranty information, please contact Airia Brands 511 McCormick Blvd. London ON N5W 4C8 T 1-855-247-4200 F 1-800-494-4185...
  • Page 3 The energy recovery core inside the Lifebreath ERV transfers the majority of the energy in the exhaust airstream (that you have already paid for in the way of heating or cooling your home), and uses this to condition the incoming supply air which saves you money.
  • Page 4 Recirculation modes are unavailable on some models. Note Due to ongoing research and product development, specifications, ratings, and dimensions are subject to change  without notice. Refer to www.LIFEBREATH.com for the latest product information. Warning Disconnect the power from the unit before cleaning or servicing. ...
  • Page 5 Dehumidistat Control Only the DXPL02, BC02 and BC03 controls have an adjustable Dehumidistat. ERV's are not Dehumidifiers but may have a dehumidifying effect on the ventilation air only. This greatly depends on climate, heating/cooling system being operated in the home and lifestyles of the occupants.
  • Page 6: Humidity Control

    The Lifebreath Ventilation Control 99-BC02 The Lifebreath Ventilation Control offers advanced features to control your home's ventilation. Key Features: 2 speed fan setting (LOW / HIGH)  Standby setting (fan OFF)  Humidity Electronic Dehumidistat Setting  Compatible with 99-DET02 Wireless ...
  • Page 7: Key Features

    The Lifebreath Ventilation Control 99-BC03 The Lifebreath Ventilation Control offers advanced features to control your home's ventilation. Key Features: Continuous LOW fan speed operation  Electronic Dehumidistat  Humidity 3 modes of operation:  Setting Ventilation • 20/40 Mode Indicator Recirculation •...
  • Page 8 The Lifebreath Ventilation Control 99-BC04 The Lifebreath ventilation control offers advanced features to control your home's ventilation. Key Features: 2 speed fan setting (LOW / HIGH)  Standby setting (fan OFF)  20/40 mode  Compatible with 99-DET02 Wireless ...
  • Page 9 The Lifebreath Digital Control 99-DXPL02 The Lifebreath digital control offers advanced features to control your home's ventilation. Key Features : 5 speed fan setting  Instruction Card Standby setting (fan speed 0)  Electronic Dehumidistat  20/40/60 HIGH speed override button ...
  • Page 10: Reset Button

    Timer will override the operational mode (regardless of the setting) and initiate HIGH fan speed Ventilation. Upon completion of the timer cycle, the ERV will return to your selected operational mode and fan speed setting. Lifebreath 20/40/60 Minute Timer 99-DET01 Initiates high speed ventilation for 20, 40 or 60 minutes.
  • Page 11: Replacing The Battery

    Timers (continued) Removable Lifebreath Wireless 20/40/60 Minute Timer Backplate 99-DET02 Initiates high speed ventilation for 20, 40 or 60 minutes. The 20/40/60 minute status lights indicate high speed operation. 20/40/60 Minute Status Lights Wireless Timers have an estimated range of 40' with no obstructions.
  • Page 12: Indicator Led's

    Timers (continued) Lifebreath Wireless Repeater 99-RX02 The Wireless Repeater is used to extend range of the 99- DET02 Wireless Timers. The Repeater plugs directly into a 120V power outlet. The 99-RX02 wirelessly connects to the main control as well as the 99-DET02 timers.
  • Page 13: Maintenance Routine

    Maintenance Routine 1. Inspect Exterior Hoods at Least Once a Month Make sure exhaust and fresh air supply hoods are not blocked or restricted by leaves, grass, or snow. In winter, it is especially important to make sure snow is not blocking the hoods or that frost has not built up on the wire mesh (bird screen).
  • Page 14 Maintenance Routine Continued 4. Motors — Maintenance Free 5. Drain (condensate) Line - Clean Once a Year Inspect drain line, drain spout and “P” trap for blockage, mold or kinks. Flush with warm soapy water and replace if worn, bent or unable to clean. 6.
  • Page 15 Troubleshooting SYMPTOM CAUSE SOLUTION Poor Air Flows • 1/4” (6 mm) mesh on the outside hoods is plugged • clean exterior hoods or vents • filters plugged • remove and clean filter • core obstructed • remove and clean core •...
  • Page 16 Warranty Lifebreath 130ERVD Energy Recovery Ventilators carry a 5 year Warranty on the energy recovery core and a 5 year replacement parts warranty. Register for your warranty: www.lifebreath.com or phone 1-855-247-4200 (toll free) Note: Airia will require the ERV Model and serial number(s) for the registration of your ERV.