Piping Diagram; Piping Diagram: Outdoor Unit - Daikin RXF50D5V1B Manuel D'installation

Masquer les pouces Voir aussi pour RXF50D5V1B:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
12 Technical data
12.2

Piping diagram

12.2.1

Piping diagram: Outdoor unit

PED categories of equipment:
RXF50D
7.0 CuT
k
7.0 CuT
7.0 CuT
7.0 CuT
12.7 CuT
l
12.7 CuT
m
HPS
m
9.5 CuT
a
Liquid field piping
b
Gas field piping
c
Liquid stop valve
d
Gas stop valve
e
Liquid receiver
f
Filter
g
Electronic expansion valve
h
Muffler with filter
i
Capillary tube
j1
Outdoor temperature thermistor
j2
Heat exchanger thermistor
Installation manual
14
▪ High pressure switch: category IV,
▪ Compressor: category II;
▪ Other equipment: art. 4§3.
j2
i
4.0 CuT
6.4 CuT
i
4.0 CuT
M
12.7 CuT
m
j3
m
m
o
n
j1
6.4 CuT
h
g
f
e
c
a
6.4 CuT
6.4 CuT
b
12.7 CuT
d
12.7 CuT
j3
Discharge pipe thermistor
k
Heat exchanger
l
4-way valve (ON: heating)
m
Muffler
n
Compressor
o
Accumulator
HPS
High pressure switch (automatic reset)
M
Propeller fan
Refrigerant flow: cooling
Refrigerant flow: heating
RXF50~71D5V1B
R32 split series
3P645642-2E – 2021.10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rxf60d5v1bRxf71d5v1b

Table des Matières