Cc-16 And Rs-232 Connections; Connector; Rs-232 Connector - Bose ControlSpace ESP-00 II Serie Guide D'installation

Table des Matières

Publicité

Installation Guide
pro.Bose.com

6. CC-16 and RS-232 connections

CC-16 Connector
The CC-16 connector is an RS-485 network connection for use with Bose
CC-16 zone
Figure 7. CC-16 connector location
®
controllers. Using the supplied Euroblock 3-pin labeled connector, up to 15 CC-16
DSP
GPIO 1
zone controllers can be networked to control the ESP processor or any device on the
Bose ControlSpace
control network. An external power supply is required. Note that in
®
addition to wiring the A and B terminals, it is highly recommended to connect the ground
terminal from the ESP processor to each CC-16 zone controller. The maximum distance
from ESP processor to any CC-16 is 2000 feet (610 m).

RS-232 Connector

The RS-232 connector provides a DB-9 male connector (type DTE) for communication
Figure 8. RS-232 connector location
between the ESP processor and other serial-controlled devices including third-party
DSP
GPIO 1
control systems.
The default serial port settings are 38,400 baud, 8-bits length, 1 stop bit, no parity, and no flow control. If required these settings can be
changed using ControlSpace
Designer™ software.
®
The document ControlSpace
Serial Control Protocol (downloadable from pro.Bose.com) outlines all supported command strings and
®
functions available to control/query Bose ESP processors and PowerMatch
power amplifiers.
®