USING THE BY-PASS
In order to save power consumption, the UltraBead lters come including a by-pass system that allows to bypass the
multiport valve during Filtration. This can save up to 30-40% energy (depending on pressure loss and pump type).

CLEANING PROCEDURE

FILTRATION
During FILTRATION the 2 slide
valves are in fully open position
and the Multiport valve is in
FILTER position (see photo).
1. RINSE WITH AIR
1. Stop the pump and close the two
slidevalves.
2. Move the Multiport valve from
FILTER to RINSE position (see photo).
3. Now start the blower to separate
the waste particles from the beads.
You can use the blower for 2-3
minutes.
4. Stop the blower and start the pump
to re ll the tank with water. When the
water has reached the top of the lid
you can stop the pump.
NOTE: in order to save water during
backwash you can repeat steps 3 and
4 to perform an extra rinse with air.