REFILLING WITH WATER
When the low water indicators (4,34) turn ON, turn the boiler activation switch (3) OFF. Let the unit cool down for 10 minutes and press
the steam release trigger until all steam pressure is released. Once the boiler has no more pressure left or when cold, you can safely open
the cap and refill. Refill with 2 bottles of water (0.5 gal / 1.8L) and refasten the boiler cap. If you add too much water in the boiler, steam
will be more humid and wet. Leave space for steam!
IMPORTANT:
Never open the boiler cap when under pressure.
IMPORTANT:
Never put anything else other than clean water in the boiler.
FEATURES
This model is equipped with the following features:
LOW WATER INDICATORS (4,34)
A red warning light signals that the water needs to be refilled. If you wish to continue steam cleaning, see the "Refilling with Water"
instructions.
VARIABLE PRESSURE CONTROL (12)
With the steam pressure regulator, it is possible to select the steam pressure that you wish to use during your cleaning
from minimum, medium and maximum (12).
STEAMREADY™ INDICATOR (5)
Lets you know when the steam cleaner is operating at optimal pressure and ready to use.
All manuals and user guides at all-guides.com
ADI™ DISPLAY (6)
TEMPERATURE AND PRESSURE DISPLAY
While the steam cleaner is ON (number 2A, 2 and 3), the temperature indicated on the display is in °F. To display the operating
pressure in psi, press and hold the button (3). After 10 seconds, the display will return to the operating internal temperature.
HOUR COUNTER
This device is equipped with two hour counter; C1 and C2. C1 is fixed and C2 is resettable by the user. To display them, turn off the unit
with the power button (2), then press the boiler activation button (3); every time you will press the button (3) the display will show
respectively the hour counter C1 and the hour counter C2.
RESETTING THE HOUR COUNTER C2
Turn the steam cleaner off by pressing main power switch (2A) located in the rear side of the unit.
Press both buttons (2) and (3) and hold them; in the meantime turn the machine on by pressing the main power switch (2A).
MAINTENANCE REMINDER DESCALE BOILER
The steam cleaner is equipped with a maintenance reminder which indicates descale boiler on the display alternating with the
temperature. When the display indicates DESCALE BOILER, it is time to perform a boiler maintenance. Let the steam cleaner cool down
for at least 8 hours before proceeding. Please refer to the maintenance instructions on page 13 to complete the boiler maintenance.
USING THE ACCESSORIES
CONNECTING THE HOSE (10)
Insert the steam hose connector (15) into the steam hose connection outlet (7) all the way, making sure it cannot be pushed in further.
Ensure the hose locking pin (16) is in place.
WARNING:
This hose contains electrical connections, do not immerse in water for cleaning.