When using the lance with or without the brushes, you will need a cloth to wipe off the moisture and dirt that has been lifted
through cleaning.
IMPORTANT:
Always respect the surface that you are cleaning, adhere to the surface cleaning instructions and do a colour
test on a hidden section before you begin cleaning.
STEAM SCRAPPER (28)
The steam scrapper (28) is used for removing stickers, wallpapers and adhesives. Attach it to the lance (23).
PLUNGER TOOL (29)
The plunger tool (29) is used to unclog drains. Attach the plunger tool to the lance (23), place the tool firmly on the drain
and blow the steam inside the drain for a few seconds. Steam will melt away residue and remove odors.
ORDER MORE ON DUPRAY.COM

MAINTENANCE

MAINTENANCE OF THE BOILER
To maintain your steam cleaner in good condition and to ensure constant performance, we recommend that you periodically clean
the boiler after every 20 hours of use or less depending on the water hardness. The ADI™ will display DESCALE BOILER when the boiler
needs to be maintained.
All manuals and user guides at all-guides.com
CLEANING INSTRUCTIONS
WARNING: Before cleaning the boiler, please make sure that the boiler is at room temperature, that it has not been used
for at least 8 hours, and that the steam cleaner is disconnected from the power source.
1.
Unscrew and remove the boiler drain cap (8), use the provided Allen key. Empty all the remaining water in the boiler.
Put the boiler drain cap back on.
2.
Remove the boiler cap (1). Using the refilling bottle (31), refill the boiler with equal parts of water and white vinegar
(for a maximum of 700 ml or 23 oz) and leave the boiler cap (1) open.
3.
Let sit overnight.
4.
Remove the boiler drain cap, drain the boiler and rinse thoroughly with clean water.
5.
Refill with 1.8L (or 0.5 gal) of water and put the boiler cap back on.
6.
Connect to a power outlet. To reset the DESCALE BOILER display, turn on the appliance by activating the switch (2A) and the power button (2),
then press again the power button (2) and keep it pressed for approximately 10 seconds, the DESCALE BOILER indicator will disappear
from the display and will only appear at the next maintenance interval.
WARNING:
It is not recommended that you use any other chemical to clean this product. Doing so will automatically void the warranty.
ATTACHMENT COUPLINGS
If the attachment connections dry up after intensive use, put a small amount of petroleum jelly (Vaseline)
around the O-rings on the male attachment.
en