Photoelectric Control:
Photoelectric control receptacle should be oriented
before control is installed.
Loosen the two holding screws and rotate receptacle
until "North" is directed to true North.
gaps that could allow water to enter the fixture.
Tighten holding screws and install control.

Electrical Connection:

Connect Luminaire wire leads to supply wire.
Connections are to be made in interior of pole.
Replace pole cap. A wiring diagram is provided on a
label inside luminaire for reference.
Note that care should be exercised not to pinch leads
between door and housing or door and internal
power supplies when closing the door.
Wired Dimming Control (If Applicable):
Gray Lead = 0VDC (-)
Dimming Input/Output
Control Voltage
1
Low (0-1.25V)
Nominal Input Wattage
2
10% of Max
Nominal Lumen Output
2
Linear Transition between Low and High
1
2
Component and system tolerance may affect the
end point levels and linearity of transition
PE Dimming Control:
All dimming control connections are made through
the unit's or luminaire's PE Receptacle.
Refer to instructions included with GE Dimming PE
Control regarding appropriate settings for dimming
control.
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in
connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not
covered sufficiently for the purchaser's purposes, the matter should be referred to GE Lighting.
All trademarks are the property of their respective owners. Information provided is subject to
change without notice. All values are design or typical values when measured under laboratory
conditions. Current, powered by GE is a business of the General Electric Company.
© 2017 GE.
www.currentbyge.com
High (10V)
100%
GEH6049 (Rev 0
Occupancy Sensor (optional):
The occupancy sensor ships with default programming
which may be modified using the sensor's
programming button.
Separate programming instructions are included.
Supplemental information on occupancy sensor
behavior with GE LightGrid
Visit www.LED.com for more informantion.
4

MAINTENANCE / CLEANING

WARNING
Risk of electric shock. Make certain power is off before
attempting any maintenance.
To maintain light output, occasional cleaning of the
outer lens surface may be needed.
pH (pH 6 to 8) containing no chlorinated or aromatic
hydrocarbons.
and wipe dry.
5
STORAGE
Packaged units should NOT be stored unprotected
outdoors in corrugated boxes (cardboard boxes).
exceeding -40°C (-40°F) to 50°C (122°F) such as a
roofed area or covered with a secured tarp to keep
water off the corrugated (cardboard) packaging.
/1 ) Eng
is available.

Publicité

Table des Matières
loading

Table des Matières