1
UNPACKING/HANDLING
This luminaire has been packed to ensure no damage
during transit. Inspect to confirm.
Do not impact or stack luminaire after unpacking.
2
MOUNTING
Risk of injury or damage. Unit will fall if not installed
properly. Follow installation instructions.
Follow installation instructions for the selected mounting
method:
a. Slipfitter
b. Round Pole Architectural Arm
c. Square Pole Architectural Arm
d. Knuckle Slipfitter for 2 3/8 in. (60mm) OD Vertical
Tenon (0 to 45° vertical aiming angle)
2a. Slipfitter
1 1/4 inch (1.660 OD) through 2 inch (2.375) O.D. pipe.
Adjust the clamp bolts so the opening is slightly larger
than pipe.
and sits on the center leveling steps extended from
top of housing.
steps.
up bolts (4-5 foot-pounds).
— If upward tilt is needed, loosen the bolts slightly, lift
luminaire and shift pipe to the next leveling step.
— If downward tilt is needed, shift pipe to sit on a
more rearward step.
alternating between bolts.
Under no conditions should slipfitter bolts be torqued to a
level greater than 14 foot pounds (19 N-m).
Pipe Clamp
WARNING
WARNING
FIGURE 1
2b. Round Pole Architectural Arm
This luminaire has been configured to mount to a round
poles 2.38 to 6 inches (60-152 mm) in diameter. Hole
pattern on round pole shall be in accordance with Figure 2.
Under no conditions should architectural arm mounting bolts
be torqued to greater than 32 foot pounds (43 N-m)
DRILLING TEMPLATE ROUND POLE MOUNTING
2.38 to 6 inch (60 to 152 mm) OD Round Pole Mounting Arm
(See Figure 3.) to desired hole spacing and tighten set
screw on plate.
shown and tighten into nut plate. (See Figure 4.)
Install 3/8 bolt, lock washer and washer below
arm as shown and tighten into nut plate.
hole pattern that lines up with keyhole slot (see Figure 5)
Torque top and bottom bolts to 25 - 32 ft-lbs (34-43 N-m).
Inspect installation to ensure fixture is secure.
FIGURE 3
FIGURE 4
WARNING
FIGURE 2
FIGURE 5