Preparation for Operation
We recommend the use of a pre-filter and suction equipment consisting of a suction hose, a
suction strainer and a non-return valve. This will prevent damage to the pump from stones and
other solid foreign objects.
a) General Information
The water to be pumped must be clean and clear. Only fine suspended matter is admissible, which may
occur in every normal garden pond. Coarser impurities (leaves, dirt particles, pebbles etc.) clog the
suction port or block the pump.
b) Suction Port
Screw a suction hose onto the suction port. If necessary, seal the screw connection with sealing tape.
The suction hose should feature a suction valve. If the suction valve cannot be used, a non-return valve
should be installed.
Lay the suction hose so that it inclines upwards from the water intake point towards the product. The
suction hose should not lie higher than the product, otherwise air bubbles will form, which will make it
difficult to pump the water.
Make sure that the suction valve of the suction hose is deep enough in the water intake point (at least
10 cm below the water surface) so that the product does not run dry when the water level drops.
Make sure that the suction port is completely sealed. Otherwise air is drawn in instead of water.
c) Pressure Port
The pressure hose should be able to withstand the maximum discharge rate of the pump (see

"Technical data").

If you want to use a pressure hose featuring a quick-release connector, screw the hose adapter
into the pressure port.
Connect a pressure hose to the pressure port.
Open existing locking mechanisms (e.g. spray nozzles, valves). This allows the air present in the suction
line to escape.
d) Inserting the Battery
The product is delivered without a battery and charger. You can find information on suitable
batteries and chargers in the "Technical data" chapter.
Do not use batteries and chargers from other manufacturers.
Charge the battery fully and insert it into the battery compartment. Close the battery compartment.
Operation
Switching the product on/off
1. Place the product on a flat, firm surface.
2. Fill the product with water through the water filler openings. This accelerates the suction process.
After you have filled the product with water, close the water filler openings airtight with the screw
caps.
3. Switch the product on with the on/off switch. The product immediately starts up and starts pumping water.
Position
Meaning
I
Energy-saving operation (reduced power)
O
Product switched off
II
Normal operation
4. Switch off the product after operation.
If you want to use the product again at another time, fill the product again with water through the
water filler openings.
Indicator Lights
Signal
3 LEDs light up
2 LEDs light up
1 LED lights up
Removal from Service
Should the product be taken out of service (e.g. for cleaning, maintenance or storage for winter), then
proceed as follows:
Remove the battery from the product.
Disconnect the hoses from the product and dry them.
Let the remaining water drain out of the product through the water outlet opening.
Dry up the product. If required, clean the housing.
During winter, keep the product in a dry space protected against frost.
Meaning
Remaining battery capacity: 100 %
Remaining battery capacity: 60 %
Remaining battery capacity: ≤30 %
Troubleshooting
Fault
Cause
Battery empty.
Pump does not run or suddenly
Battery damaged.
stops.
Other defect.
Contaminated water.
Hose/pre-filter clogged.
Hose damaged.
Suction hose material too soft/
thin.
Pump draws in too little water or
no water at all.
Air inside the pump.
Suction hose not deep enough
in the water.
Suction port not sealed.
Product switches off automati-
cally due to overheating.
Pump only runs for a short time.
Water temperature >35 °C.
Drive impeller damaged.
Care and Cleaning
The product is maintenance-free. There are no serviceable parts inside the product.
If the product has not been operated for a long period of time, make sure that the drive impeller is running
properly. To do this, switch the product on briefly and then off again immediately.
If the pump is blocked, connect a water hose to the pressure port and remove the cap at the suction
port. Turn on the faucet and switch on the product several times for about 2 seconds. This will clear
blockages in most cases.
Remove the battery from the product before each cleaning.
Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as they can
cause damage to the housing and malfunctioning.
Use a soft clean cloth to clean the outer surface of the product. If necessary, you can use a damp cloth
and a mild cleaning agent.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the household waste.
At the end of its service life, dispose of the product in accordance with applicable regulatory
guidelines.
Remove the battery and dispose of it separately from the product.
You thus fulfill your statutory obligations and contribute to the protection of the environment.
Technical Data
Operating voltage ................................. 20 V/DC
Protection type ...................................... IPX4
Discharge head .................................... max. 15 m (switch position I)
max. 22 m (switch position II)
Suction height ....................................... max. 5.5 m
Discharge rate ...................................... max. 2000 l/h, with G1 hose connection (switch position I)
max. 2800 l/h, with G1 hose connection (switch position II)
Hose connection ................................... G1
Particle size (filter) ................................ max. 0.5 mm
Water temperature ................................ max. +35 ºC
Suitable batteries and chargers are available from Conrad under the following item numbers:
Battery .................................................. 1881809, 1881810, 2331500
Charger ................................................. 1881811, 1881812
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2020 by Conrad Electronic SE.
Solution
Remove and charge battery.
Replace battery.
Product must be repaired by a
specialist.
Clean pre-filter.
Rinse hose with water, clean
pre-filter.
Replace hose.
Use harder/thicker suction hose.
Fill the product with water
through the water filler open-
ings.
Suction valve must be at least
10 cm below the water surface.
Seal suction port with sealing
tape.
Before switching on again:
Clear blockages and ensure
sufficient cooling.
Water temperature must be
below 35 °C.
Product must be repaired by a
specialist.