3. CONNECTIONS

3.1. CONNECTIONS
OPEN THE "RT COM" TIME BASE:
Open the terminal box which have inside the 6 black terminal
Connect the wires n°2 and n°4 to the GND terminal on the position sensor input
terminal block.
Connect the wire n°5 to the "MIN" terminal.
Connect the wire n°3 to the "12 Hrs" terminal.
connect the sensor wires between the GND and MIN terminals.
Open the terminal box labelled "230Volts":
Connect COM to COM, A to P1 and B to P2 on the motor control terminal block.
Connect the 230 VAC power supply to the "Entrée Alim. 230Volts" terminal, taking
care to connect the "TERRE" wire in the middle.

3.2. CONTROL AND MONITORING DEVICES

LD1: Mains present indicator light
LD2: Light indicating synchronisation with the received code:
Lights as soon as the received code is correct.
Flashes if there is temporary interference of the received code.
Light off when there has been no code for 24 hours.
LD3: Light indicating monitoring of the received code:
Flashes as the synchronisation code is received.
SW1: Switch for resetting the hands to midday
ON: Position fixed at midday
OFF: Automatic time reset starting at midday.
MAN P1 and MAN P2: Manual motor forward operation keys.
SW2: Switch for programming the time zones
MDE-RTcom-3024V1.5
AND CONTROL AND MONITORING DEVICES
Note: For clocks with minute control only,
(for tests only)
17