Temperature controller
1.0
GENERAL CARACHTERISTICS
The controller (pic.1) is studied for the management of water fireplaces. Its versatility allows a wide range of uses:
Exercise economy
Management of the different integration sources
Management of a mixed heating circuit (mix valve and pump).
Protection functions
Maximum and minimum working adjusting temperature.
Protection for overheating.
Anti freezing of the output's powers.
Power outputs anti block program.
Operative Functions
All the adjustments can be done through the controller.
All the adjustments and the functioning running can be seen through the display and the leds.
The display and the led allow the visualisation of the read temperature, the control of the devices and the signal of failures.
2.0
PRODUCT' S COMPOSITION
♦ Temperature controller 4 modules for AVE and VIMAR plates, engaged with internal connector for electrical
connection devices as described in par. 3.3
♦ Plate
♦ Box
♦ N. 02 probes length 2,00 met. with sheath
♦ User's manual
3.0

INSTALLER' S MANUAL

All the operation have to be done by export and qualified people. Wrong changing of the parameters could damage
the product and due to a wrong functioning of the same.
3.1
INSTALLATION'S RULES
ATTENTION
In order to allow the correct functioning and avoid damages to the electrical and electronic parts:
-
Set the controller in a dry place and away from heating sources;
-
Avoid to put together probe's cables with power's cables;
-
Set the probe in order to read the temperature correctly, avoiding the direct or indirect contact with the flame;
-
Set the probe 1 in the nearest place to the warm water source or in the collector.
-
Provide the system of a bipolar switch according to the rules and with open contact's distance of at least 3 mm each
pole;
-
Only prepared people could install the device, according to the rules.
-
Before the connections make sure the electricity is not connected.
3.2
PREPARATION OF THE INSTALLATION
Dimension of the drilling
The dimension for the controller are 130 x 73mm, depth 52 mm. the frontal part is 144 x 82 mm.
It is possible to install the controller with the wall box that is sold separately.
Pag.: 49/60
TC 120
User's Manual
OFF
L4
Fig.1 – External aspect
Cod. 004770370
L1
L2
AUX
L3
MENU
TC120

Publicité

Table des Matières
loading