Istruzioni, instructions Instrucciones
Calibrating the microswitches with the geared motor installed on the right
Closing:
With the geared motor released, close the gate to point wanted; turn the bottom cam clockwise
until the bottom microswitch trips and then lock it with the relative screw.
Opening:
With the geared motor released, open the gate to position wanted and turn the top cam
counter clockwise until the top microswitch trips and then lock it with the relative screw.