TRI-LITE HVLS SERIES FANS
GUY WIRES
The package includes:
(4) Cable 3mm SS (66' length provided to equal 4 @ 16.5')
(8) Thimbles 6mm SS
(16) Cable Clamps 3mm
*DO NOT USE TURNBUCKLES*
GEAR MOTOR
TAB ON FAN FRAME
HUB
(BLADES NOT
SHOWN)
FIGURE 9
Fig.15
STRUCTURAL NOTE:
STRUCTURAL NOTE: Guy cables must be installed
or fastened to a structural component of the building at
or fastened to a structural component of the
the angle shown in Figure 9 and Figure 11.
building at the angle shown in Fig.15 and Fig.17.
TRI-LITE HVLS-M (04_29_15)
Beam
Drop
Guy cables must be installed
Extra hardware required:
(4) Forged Eye Bolts M6-1.0 x 100mm
(4) Nuts M6-1.0
(4) Nylocks Mg-1.0
(8) Washers Flat M6
Eye Bolt
Thimble
Clamps
Guy Cable
CEILING/ROOF DECK
Guy cables should be
taut but not overstressed to
allow free self-leveling
When placing cable clamps on the
wire, it is imperative that the U-
bolt side of the clip is placed on
the short turn-back side and the
saddle goes on the long side. (The
o
o
45 to 60
"live" end).
FIGURE 10
I-Beam
Nut
Washer
Nylock
Washer
Fig.14
FIGURE 8
GUY CABLE
TURN-BACK
SIDE
(3mm)
SS CABLE
U-Bolt
Saddle
Thimble