7
WARNING!
•
Check the condition of the cable and switch.
•
Adhere to the voltage (V) and frequency (Hz) requirements indicated on the machine.
•
Made electrical grounding connection (yellow-green), using an IP 67 outlet (2p + earth) protected by
a thermal magnetic differential circuit breaker IΔN 0,03A.
•
Periodic checks of residual current circuit-breaker operation must be carried out.
T
•
If an extension lead is required, only use a IP67 plug and socket and a 3x2,5 mm2 cable type H07RN-
F.
•
Make sure the power supply cable is positioned safely so that it does not hinder machine movements
and is not subject to friction or damaged during operation.
•
The machines must be isolated before removing guards,
supplying of the basin with coolant (water),
replacement of diamond blades and/or spindle.
•
Models fitted with residual current circuit-breaker for
protection against electric shocks, and equipped with
low voltage coil to prevent inadvertent machine activation. Periodic checks (TEST).
•
Avoid forcing the machine when cutting.
•
Single phase motor IP 55, negligible radio interference.
•
In all cases of malfunction of the switch, power cable or motor, consult a qualified electrician or our
technical department.
8
Instructions for handling and transport
Art.
915-916
9
Fitting the diamond cutting tool,
supplying of the basin with coolant (water)
6
T
1
®
1
(kg)
16
3
1
2
1+2
(kg)
(kg)
0,5
16,5
1
2
2
M max
(kg)
21
2
4
2
3
1