22. Troubleshooting
Fault
Cause
Motor does not run
No electricity
Chain brake
Chain does not move
Chain brake
Poor cutting performance
Blunt chain
Chain wrongly fitted
Chain tension
Saw works only with difficulty
Chain tension
Chain jumps off sword
Chain becomes hot
Chain lubrication
Never use tools with defective On/Off switches.
In the case of all other types of technical faults, please contact an authorized Customer Service workshop, our
Central Service Department, or your local dealer.
22
13:00 Uhr
Seite 22
Remedy
Check socket, cable and plug.
Damaged cable: Have repaired by
Customer Service. It is prohibited to patch
the cable with insulating tape.
Damaged switches have to be replaced
by a Customer Service workshop.
See section 16 and 17 „Chain brake" and
„Releasing the chain brake".
Check the chain brake, release if
necessary.
Sharpen the chain
Check that the chain is fitted correctly
Check the chain tension
Check the chain tension
Check oil level
Check chain lubrication