Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

security
2.3

Power Supply

After the unit is fixed at the wall, connect again the AL35SW power supplier/battery
charger to 12V7Ah battery. It's important to know that the Central Unit is powered exclusively
by the 12V7Ah lead battery which is costantly in charge.
Look out of connection polarity to avoid damaging the product.
After the connection of the battery, you can connect the main power supply on the 220V
clamps of the power supplier/battery charger.
CAUTION !
Main power supply has to be connected by two 1,5mmq wires coming from a
sectioning switch (i.e. a magneto-thermic protection switch), used only for the
burglar central unit.
12V7Ah battery must always be connected. If you want make sure of its charge
status, disconnect the main power supply and measure the tension by a
volt-meter.
Do not connect on 13Vcc
(clamp "+12V") a load beyond 330mA.
Do not connect on sirens outputs of the Central Unit (clamp "+sir.") a load
beyond 3A.
230V~
50Hz
Sezionatore
services power supply output of the Central Unit
Battery
12V7Ah
TO OPEN THE COVER OF THE ANTENNA
IN ORDER TO CONNECT IT TO THE CABLE
THAT EXITS FROM CENTERS THEM
Installation
GND ANT
31

Publicité

Table des Matières
loading

Table des Matières