Minimum Ambient Temperature Rating
Fuel Consumption per 20 lb. Cylinder
WARNING: This product
contains and/or generates
chemicals known to the State
of California to cause cancer or
birth defects, or other reproduc-
tive harm.
WARNING: Not for home or
recreational vehicle use.
The heater is designed and approved for use
as a construction heater in accordance with
Standard ANSI Z83.7 • CSA 2.14. Check with
your local fire safety authority if you have
questions about applications.
Other standards govern the use of fuel gases
and heat producing products in specific ap-
plications. Your local authority can advise you
about these.
The intended use of this heater is the tempo-
rary heating of buildings or structures under
construction, alteration or repair.
ASPHYXIATION HAZARD
• Do not use this heater for heating human
living quarters.
• Do not use in unventilated areas.
• The flow of combustion and ventilation
air must not be obstructed.
• Proper ventilation air must be provided
to support the combustion air require-
ments of the heater being used.
160220-01B
SPECIFICATIONS
Rating 10,000 - 15,000 Btu/hr
Type of Gas
Ignition
Gas Supply Pressure
to regulator
Manifold Pressure
www.usaprocom.com
PCTT15
(3.0 - 4.4 kW)
Propane/LP Only
Max - Tank Pressure
Min - 20 psi (1.37 bar)
9 - 17 psi (0.62 bar - 1.17 bar)
36 Hours
SAFETY
• Refer to the specification section of
the heater's manual, heater data plate,
or contact ProCom Heating, Inc. to
determine combustion air ventilation
requirements of the heater.
• Lack of proper ventilation air will lead
to improper combustion.
• Improper combustion can lead to car-
bon monoxide poisoning leading to
serious injury or death. Symptom of
carbon monoxide poisoning can include
headaches dizziness and difficulty in
breathing.
1. Keep children and animals away from
heater.
2. Never operate heater while sleeping or
unattended.
3. Check the heater thoroughly for damage.
Do not operate a damaged heater.
4. Do not modify the heater or operate a
heater which has been modified from its
original condition.
5. Use only propane/LP gas.
6. Use only vapor withdrawal propane/LP
supply. If there is any question about
vapor withdrawal, ask your propane/LP
dealer.
7. For indoor use only. Adequate ventilation
must be provided. Provide minimum open-
ings of 1 sq ft (0.093 m²) near the floor and
1 sq ft. (0.093 m²) near the ceiling. Do not
use inside house, camper, tent, vehicle, or
any type of unvented or enclosed area.
PCTT30
10,000 - 30,000 Btu/hr
(3.0 - 8.8 kW)
Match Light
0° F (-17.8° C)
18 Hours
3