IS 10 T
GB
Repeated attempts at starting with negative outcome
may cause excess accumulation of water in the
exhaust system with possible serious damage to the
engine.
If it is difficult to start the engine, do not insist for too
long without first having closed the sea intake cock
[Fig. 6 Ref. 2].
Before stopping the generator it is recommended to
let it run for a few minutes without drawing electric
current, in order to allow the engine and the alternator
to cool down.
GB
- 16
The low oil pressure protection does not give an
indication of the level of engine oil in the sump.
Therefore, check this level daily.
The engine functions properly if it does not exceed an
inclination of maximum 30º for less than 3 minutes,
25º without time limit, both on the longitudinal and
the transverse axis. If the engine is operated at a
greater inclination, the risk is insufficient lubrication
or aspiration of engine oil through the air filter.
In the event of one of the above described protections
intervening, after ascertaining and removing the cause
of the intervention, press the STOP button to reset the
control panel (otherwise the signal would remain in
memory preventing the engine from starting).