5.
If you would like to measure without the weighing container, remove it from the
weighing platform and press the button Z/T. Any tare weight value will be displayed
as a negative number once all weight is removed from the scale.
The weighing capacity of the weigh scale includes the weighing container.
Therefore, it is recommended to use a weighing container which is as light as
possible.
c)
Counting mode
This function determines the quantity of units of an equal weight.
1.
Press and hold the button C until the number "25" appears on the screen and the
letter "C" flashes on the left.
2.
Press the button MODE to set the reference unit number (25, 50, 75, 100).
3.
Place exactly the number of objects on the weighing platform as you have set as
the reference unit number.
4.
Press the button C. The display will show the number of units. The letter "C" on
the left will stop flashing.
5.
Now place the objects to be counted on the weighing platform. The display will
show the number of units.
6.
To return to normal weighting mode, press the button MODE.
The reference value will be stored until you set a new value. Return to the
counting mode by pressing the button "C" in normal weighting mode.
d)
Calibration
Calibrate the scale regularly, especially when it has not been used for a long time. To
calibrate the scales you need two standard weight of 100 g and 200 g (not included
in delivery).
1.
Press and hold the button MODE until CAL shows on the screen.
2.
Press the button MODE again, the letters CAL will start flashing and the first
calibration weight, 100.00 g will show on the screen.
3.
Gently place a standard weight of 100 g on the weighing platform.
4.
The second calibration weight, 200.00 g will show on the screen.
5.
Remove the 100 g standard weight from the weighing platform.
6.
Gently place a standard weight of 200 g on the weighing platform.
7.
The word "PASS" will show on the LCD. Remove the weight and turn off the scale.
The calibration process has been completed.
INDICATIONS
Indication
Cause
O-LD
The weighing object exceeds the
weighing range.
Lo
The battery voltage is so low that
the scale cannot function properly.
UnSt
The scale is in an unstable status.
The reading on the LCD is not
ready to be used.
H (flashing) The scale is not in a stable state.
The reading on the LCD is not
ready to be used.
H
The scale is in a stable status. The
reading on the LCD is ready to be
(steady)
used.
o
The reading is set to zero.
Solution
Remove the weighing object
from the scale immediately to
avoid damage to the scale.
Replace the batteries
immediately.
•
Restart the scale.
•
Make sure the scale is on a
stable surface.
•
Do not remove / put objects
on the weighing platform
when the scale is starting
up.
---
---
---
DISPOSAL
a)
Product
Electronic devices are recyclable waste and must not be disposed of in the
household waste!
At the end of its service life, dispose of the product according to the relevant
statutory regulations.
Remove any inserted (rechargeable) batteries and dispose of them
separately from the product.
b)
(Rechargeable) batteries
You as the end user are required by law (Battery Ordinance) to return all used
batteries/rechargeable batteries. Disposing of them in the household waste is
prohibited!
Contaminated (rechargeable) batteries are labelled with this symbol to
indicate that disposal in the domestic waste is forbidden. The designations
for the heavy metals involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead
(name on (rechargeable) batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your
municipality, our stores or wherever (rechargeable) batteries are sold.
You thus fulfil your statutory obligations and contribute to the protection of the
environment.
TECHNICAL DATA
Operating voltage .................... 3 V, 2 x battery type AAA.
Current consumption ............... max. 10 mA
Weighting capacity .................. max. 200 g / 7.055 oz / 1000 ct / 6.43 ozt
Resolution: ............................... 0.01 g / 0.0005 oz / 0.05 ct / 0.0005 ozt
Accuracy: ................................. 0.06 g / 0.003 oz / 0.3 ct / 0.003 ozt
Automatic power-off time: ........ 2 mins
LCD size: ................................. 45 x 29 mm
Weighing platform size ............ 55 x 50 mm
Operating temperature ............ +5 to + 35 ºC
Operating humidity .................. <70 %
Storage temperature ................ -10 to +60 ºC
Storage humidity ...................... <85 %
Dimensions (W x H x D) .......... 64 x 22 x 108 mm
Weight ..................................... 91 g
Legal notice
These operating instructions are a publication by Voltcraft®, Lindenweg 15, D-92242 Hirschau/Germany, Phone +49 180/586 582 7
(www.voltcraft.de).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© Copyright 2011 by Voltcraft®