SECTION 7 |
INVERTER PARAMETER
INPUT
BATTERY SYSTEM VOLTAGE
NOMINAL INPUT VOLTAGE
INPUT VOLTAGE RANGE
MAXIMUM INPUT CURRENT
INPUT CURRENT AT NO LOAD
OUTPUT
OUTPUT VOLTAGE WAVE FORM
OUTPUT VOLTAGE
OUTPUT FREQUENCY
OUTPUT POWER, CONTINUOUS (RESISTIVE LOAD)
OUTPUT POWER, SURGE (<1 SEC., RESISTIVE LOAD)
PEAK EFFICIENCY
USB CHARGING PORT
PROTECTIONS
LOW INPUT VOLTAGE SHUTDOWN
HIGH INPUT VOLTAGE SHUTDOWN
OVERLOAD AND GROUND
FAULT SHUT DOWN
OVER TEMPERATURE SHUTDOWN
COOLING FAN
INPUT FUSE: INSIDE TOP OF THE 12V POWER
PLUG PORTION
CONNECTIONS
DC INPUT CONNECTION
AC OUTPUT CONNECTION
MONITORING
STATUS INDICATION
Specifications
SAM-100-12
12 VDC
13.8 VDC
10.5 ± 0.3VDC to 15.5 ± 0.3VDC
10A at 13.8VDC
< 0.35A
Modified Sine Wave
115 VAC (108 to 127 VAC)
60 Hz (56 to 64 Hz)
100W
200W
> 85%
Connector Type "A": 5.0 ± 0.2VDC, 2.1A
≤ 10.5 ± 0.3VDC
Auto reset at 11.6 ± 0.3VDC
≥ 15.5 ± 0.3VDC
Auto reset at 15.2 ± 0.3VDC
Overload: >125W
Ground Fault Leakage Limit: 4 to 6 mA
Latches in shutdown condition. Manual
reset: Remove the inverter from the 12V
Power Outlet. Wait for 3 min and re-insert
firmly.
Yes. Auto reset on cooling down.
1 - Always ON.
12A, 250V (Fast Acting, Type AGC-12;
Dimensions: 0.25" x 1.25")
12 V Power Plug (Cigar Plug)
One NEMA5-15R Outlet
GREEN LED: ON - NORMAL; OFF - SHUT
DOWN
SAMLEX AMERICA INC. | 11