To learn more...
Operation mode
AUTO : During operation mode selection the POWER indicator blinks.
• Unit selects operation mode every 10 minutes according to setting temperature and room temperature.
HEAT : Unit takes a while to warm up. The POWER indicator blinks during this operation.
COOL : Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL mode.
DRY
: Unit operates at low fan speed to give a gentle cooling operation.
FAN
: To circulate air in the room.
ECONAVI and AUTO COMFORT
ECONAVI
COMFORT
or
The unit will start to initialize
(for approximately 1 minute)
Human activity sensor operation
ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy.
Mode
COOL/DRY
HEAT
AUTO COMFORT ; Detecting human presence and activity, the unit controls room temperature to keep human
comfortable consistently.
Mode
COOL/DRY
HEAT
ECONAVI and AUTO COMFORT
Precise control of temperature during low activity to maximize energy saving.
Mode
COOL/DRY
* During low activity, fan speed 1 tap up for first 15 minutes or until set temperature is reached.
** During human absence, maximum fan speed for COOL/DRY mode is medium fan.
8
AUTO
The human activity sensor
will start to detect.
Human
Low activity
Set
temperature
Human
Low activity
Set
temperature
+1 tap*
Set
Fan Speed
Human
Low activity
Set
temperature
Normal activity
+2°F / +1°C
Normal activity
+2°F / +1°C
+0.5°F / +0.3°C
ECONAVI and AUTO COMFORT take advantage of
the human nature that human being takes time to feel
the temperature rise during low activity level; the unit
adjusts temperature to maximize energy saving
without sacrificing the comfort.
High activity
Absent
-4°F / -2°C
High activity
Absent
-2°F / -1°C
-4°F / -2°C
+1 tap
+4°F /
+2°C
-4°F /
-2°C
+4°F /
+2°C
-4°F /
-2°C