30 | English
Digital laser measure
Max. transmission power
A) When measuring from the front edge of the measuring tool, this applies for high reflectivity of the
target (e.g. a wall painted white), weak background lighting and a 25 °C operating temperature; a
distance-dependent deviation of ±0.05 mm/m must additionally be factored in.
B) When measuring from the front edge of the measuring tool, this applies for high reflectivity of the
target (e.g. a wall painted white), strong background lighting, 25 °C operating temperature and
large altitudes. In addition, a deviation of ±0.15 mm/m must be taken into account, depending on
the distance.
C) In continuous measurement mode, the max. operating temperature is +40 °C.
D) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by con-
densation is expected.
E) At an operating temperature of 25 °C. Charging time with 1 A USB charger. Faster charging with
the measuring tool switched off.
F) For additional technical data, visit: https://www.bosch-professional.com/ecodesign
G) When using Bluetooth® Low Energy devices, it may not be possible to establish a connection de-
pending on the model and operating system. Bluetooth® tools must support the GATT profile.
The serial number (16) on the type plate is used to clearly identify your measuring tool.
Inserting/Changing the Battery
GLM 100-25 C
Always replace all the batteries/rechargeable batteries at the same time. Only use
batteries/rechargeable batteries from the same manufacturer and which have the
same capacity.
When inserting the batteries, ensure that the polarity is correct according to the il-
lustration on the inside of the battery compartment.
Take the batteries out of the measuring tool when you are not using it for a pro-
u
longed period of time. The batteries can corrode and self-discharge during prolonged
storage.
Li-ion rechargeable battery
GLM 150-27 C
Charging the Li-ion Battery
For recharging, use a USB power supply unit whose technical data (voltage and char-
u
ging current) corresponds to that of the recommended power supply unit. Observe the
1 609 92A 7CC | (11.02.2022)
GLM 100-25 C
8 mW
GLM 150-27 C
8 mW
Bosch Power Tools