PROGRAMMING PROCEDURE (parameter setting)
• All the functions of the electronic programmer can be set in the Display menu "LCD1" using the three buttons contained therein:
- use the arrows to navigate through the menu and/or to adjust the display contrast;
- use "PROG/OK" to modify the parameter settings and/or to confirm.
T B
F I
PROGRAM
F S
CP
T B
F I
00.000.001
F S
CP
OPTIONS
OK
"PROG/OK" to confirm
SEQUENTIAL COM.
OPEN-SHUT/
OPEN-STOP-SHUT
"PROG/OK" to set
AUTO-RECLOSING
ON/OFF
"PROG/OK" to set
PRE-FLASHING
ON/OFF
"PROG/OK" to set
WARNING LIGHTS
FIXED/
INTERMITTENT
"PROG/OK" to set
(1)
INDICATOR LIGHT
FIXED/
INTERMITTENT
"PROG/OK" to set
(2)
PHOTOCELL INVERT
DURING CLOSING/
AND IN STOP
"PROG/OK" to set
Notes:
1) The indicator light flashes slowly during opening, rapidly during closing; remains lit when the
(3)
TEST FI
ON/OFF
2) FI Mode:
"PROG/OK" to set
- FI also active when the door is blocked: If the photocells are in alarm and the door is
(3)
TEST FS
ON/OFF
- FI active only during closing
"PROG/OK" to set
3) Photocell test (FI/FS)
MEMO RADIO
ON/OFF
"PROG/OK" to set
LC/CH2 OUTPUT
4) Current sensor settings:
RADIO CHANNEL/
COURTESY LIGHT
- Level 1 = motor electrical input + 2 amps
"PROG/OK" to set
- Level 2 = motor electrical input + 3 amps
- Level 3 = motor electrical input + 4 amps
EXIT
- Level 4 = motor electrical input + 5 amps
OK
- Level 5 = motor electrical input + 6 amps
"PROG/OK" to confirm
The programmer checks the electrical input to the motor, detecting any eventual increase
BACK TO OPTIONS
in effort above the normal operating limits and intervenes as an additional safety device.
5) Setting the distance from the opening travel limit:
SAFETY DEVICES
OK
"PROG/OK" to confirm
TB CONTACT
NC/8K2
"PROG/OK" to set
FI CONTACT
NC/8K2
"PROG/OK" to set
FS CONTACT
NC/8K2
"PROG/OK" to set
CP CONTACT
NC/8K2
"PROG/OK" to set
EXIT
OK
"PROG/OK" to confirm
BACK TO SAFETY DEVICES
door is blocked but not completely closed and is off when the door is completely closed.
blocked, no movement commands will be accepted (even opening commands);
In both cases activating the FI safety device during the closing stage will force travel
direction inversion.
If you enable the security test you will have to connect both the transmitter and the receiver
to the controlled load output (CTRL 24 Vdc). When the test is enabled one second will
pass between receiving a command and carrying it out.
To increase or reduce this distance modify the parameter in steps from 0 to 9 (range fro
0 to 6 cm ~). By default the appliance is set to level 4 and in this way the door will not
slam against the travel limit but will stop within a centimetre of it.
16
MOTION
OK
"PROG/OK" to confirm
TORQUE SELECTION
LEVELS 1...2
"PROG/OK" to set
(4)
CURRENT SENSOR
LEVELS 1...5
"PROG/OK" to set
LIMITED OPENING
1...9 meters
"PROG/OK" to set
(5)
DIST. FROM OPEN
0...9 steps
"PROG/OK" to set
EXIT
OK
"PROG/OK" to confirm
BACK TO MOTION MENU
DISPLAY
OK
"PROG/OK" to confirm
CONTRAST
OK
"PROG/OK" to set
ADJUST CONTRAST
0...63
"PROG/OK" to confirm
REAR LIGHTING
ALWAYS ON/
60 SEC./30 SEC.
"PROG/OK" to set
EXIT
OK
"PROG/OK" to confirm
BACK TO DISPLAY MENU