Technical Data - Miele Professional PG 8090 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15

Technical data

External dimensions:
Hard / Soft water connection:
Resin cartridge:
Resin content:
Capacity:
Minimum flow pressure:
without/with softener in
Fresh water system dishwashers: 200 kPa (2.0 bar)/600 kPa (6.0 bar)
without/with softener in
Tank system dishwashers:
Maximum static pressure:
Pressure difference:
Temperature:
Salt consumption:
Water consumption:
Reactivation time:
Capacity/Diff.:
Salt container:
Tablet shape:
14
H 572 / W 230 / D 400 mm
R 3/4"
6 x 13"
4 l +/- 10 %
Sybron Chemicals - Dow Chemical Co.
15 l/min (short periods 20 l/min)
200 kPa (2.0 bar)/600 kPa (6.0 bar)
600 kPa (6.0 bar)
maximum 100 kPa (1 bar) at 10 l/min
4 °C - 65 °C
0.5 kg NaCl/Reactivate +/- 10 %
55 l/Reactivate +/- 10 %
30 minutes +/- 10 %
+/- 10 %
10 kg
round, approx. Ø = 25 mm, h = 14 mm

Publicité

Table des Matières
loading