Model
Flow Rate
SPV-200
2.6 gpm (9.9 lpm)
SPV-410
5.9 gpm (22.6 lpm)
SPV-600
8.6 gpm (32.7 lpm)
SPV-740
11.2 gpm (42.4 lpm)
SPV-950
14.9 gpm (56.6 lpm)
SPV-1.5
1.5 gpm (13.2 lpm)
SPV-2.5
2.5 gpm (9.6 lpm)
SPV-3.5
3.5 gpm (13.2 lpm)
SPV-6
6 gpm (22.7 lpm)
SPV-8
8 gpm (30.3 lpm)
SPV-12
12 gpm (45.4 lpm)
SPV-15
15 gpm (56.8 lpm)
SPV-20
20 gpm (75.7 lpm)
Lamp installation/replacement instructions:
1. To replace the lamp, there is NO need to disconnect the system from the water supply, nor to drain the water from the reactor chamber. Lamp
replacement is a quick and simple procedure requiring no additional or special tools. The UV lamp must be replaced after 9,000 hours of
continuous operation (approximately one year) in order to ensure adequate disinfection. The controller will indicate when it is time to change
the lamp. As a measure of safety, this should be done even if the monitoring system that is included with the system indicates that the intensity
of the lamp is still in a safe region.
2. Disconnect main power source and allow the unit to power down. Remove the Safety-Loc™ connector by sliding the metal retaining ring away
from the body of the connector. Remove connector and lamp from the reactor chamber. Once you can visually see the lamp, separate the lamp
from the connector. Do not twist the lamp from the connector, simply slide the two apart. Avoid touching the lamp on the glass portion. Handling
the lamp at the ceramic ends is acceptable, however if you must touch the lamp glass, please use gloves, or a soft cloth. Fully remove the lamp
from the reactor chamber being careful not to angle the lamp as it is removed from the chamber. If the lamp is removed on an angle, pressure will
be applied on the inside of the quartz sleeve, causing the sleeve to fracture.
3. To install a new lamp, first remove the lamp from its protective packaging again being careful not to touch the lamp "glass" itself. Carefully insert
the lamp into the reactor vessel (actually inside the quartz sleeve). Insert the lamp fully into the chamber leaving about two inches
of the lamp protruding from the chamber. Next, attach the Safety-Loc™ connector on the UV lamp. The connector is "keyed" and will only allow
correct installation in one position. Ensure the connector is fully seated onto the UV lamp.
4. Once the lamp is fully seated on the connector, slide the Safety-Loc™ connector over the aluminum retaining nut. Make sure the metal
retaining ring on the Safety-Loc™ connector is pulled away from the body of the connector in order that the connector may slide fully over the
retaining nut. Once the connector is located fully over the retaining nut, slide the metal ring back in to lock the connector in place. As this
Safety-Loc™ connector is keyed to the reactor chamber, make sure the depression on the connector is located over the ground lug located on
the reactor chamber
Note: Even though the Safety-Loc™ connector contains an integral safety interlock switch which prevents the lamp from physically being
illuminated when the lamp is removed from the chamber, it is still imperative that the system be disconnected from the power source before
removing the lamp or working on the system.
VIQUA - a Trojan Technologies Company 425 Clair Road West, Guelph ON, Canada N1L 1R1
1 800 265 7246 (North America), 519 763 1032 www.viqua.com info@viqua.com
Replacement
Lamp*
S200RL-HO
S410RL-HO
S600RL-HO
S740RL-HO
S950RL-HO
S100RL-HO
S150RL-HO
S200RL-HO
S320RL-HO
S410RL-HO
S600RL-HO
S740RL-HO
S950RL-HO
* Ultraviolet lamps are rated for 9000 hours of operation. In order to ensure safe water lamps must be changed annually, with genuine Sterilight lamps.
Replacement
Quartz Sleeve
QS-200
QS-410
QS-600
QS-740
QS-950
QS-100
QS-150
QS-200
QS-320
QS-410
QS-600
QS-740
QS-950
Note: Please contact factory for list of authorized distributors in your area - t. 519 763 1032 t.f. 1 800 265 7246
System Tested and Certified by NSF International against NSF/ANSI
Standard 55 for Disinfection Performance, Class A.
Models: SPV-200, SPV-410, SPV-600, SPV-740, SPV-950
COMPONENT
Replacement Components
SPV Series
Replacement
Replacement
Controller
UV Sensor
SPC-ICE-HO
254NM-FP2
SPC-ICE-HO
254NM-FP2
SPC-ICE-HO
254NM-FP2
SPC-ICE-HO
254NM-FP2
SPC-ICE-HO
254NM-FP2
SPC-ICE-HO
254NM-FP2
SPC-ICE-HO
254NM-FP2
SPC-ICE-HO
254NM-FP2
SPC-ICE-HO
254NM-FP2
SPC-ICE-HO
254NM-FP2
SPC-ICE-HO
254NM-FP2
SPC-ICE-HO
254NM-FP2
SPC-ICE-HO
254NM-FP2
VIQUA is a brand of R-Can Environmental Inc
520068 (04/09)