17.1 Safety notices

Attention
► Only qualified electricians, who have been trained by the manufacturer, may carry out
any repairs on electrical equipment.
► Improperly performed repairs can cause considerable dangers for the user and
damages to the device.

17.2 Fault indications

In the event of a fault, an error code will appear in the display; it describes the
cause of the fault.
Display
Description
E0
No pot detected. Place a pot suitable for induction on the device.
E01,
Overheating protection or short circuit. Unplug the device and let it cool down.
E02
E03
Over- or under-voltage. Contact the customer service.
Please note
► If error messages continue to be displayed after an extended waiting period or after
restarting the appliance, then it must be sent to Customer Service to be examined.

17.3 Causes and rectification of faults

The following table assists in localizing and rectifying minor faults.
Fault
Display is empty
Please note
► If you are unable to solve the problem with the steps shown above, please contact
Customer Service.

18 Disposal of the Old Device

Old electric and electronic devices frequently still contain valuable materials.
However, they also contain damaging substances, which were necessary for
their functionality and safety. If these were put in the non-recyclable waste or
were handled incorrectly, they could be detrimental to human health and the
environment.
Ellrona Ergo Touch 3500
Possible Cause
Power plug not plugged in
Fuse switch not switched on
To Rectify
Insert plug into mains socket
Switch on fuse switch
41