17 Troubleshooting

17.1 Safety notices

17.2 Fault indications

Ellrona Comfort plus 2000 SC
This chapter provides you with important notices with regard to
operating the device. Observe the following notices to avoid
dangers and damages:
Only qualified electricians, who have been trained by the
manufacturer, may carry out any repairs on electrical
equipment.
Improperly performed repairs can cause considerable
dangers for the user and damages to the device.
In the event of a fault, an error code will appear in the
display; it describes the cause of the fault.
Display
- - -
Standby
The appliance is in Standby mode.
Unsuitable Cooking Vessel
The appliance has not recognised a suitable
cooking vessel. Use a suitable cooking vessel.
E06/08
Temperature Sensor or signal damaged
The appliance must be sent to Customer
Service for repair.
E05/07
Appliance overheating
Allow appliance to cool down. Switch appliance
off and then on again in order to acknowledge
the error, and reset.
E00/E01/E02 Voltage too high/too low
The supply voltage is not within the required
range. Use suitable socket.
E03
Open or short electric circuit
The appliance must be sent to Customer
Service for repair.
Disposal of the Old Device
Attention
Description