Programming Overview
The Analyzer control includes multiple program levels that allow
the Water Treatment Professional to customize the system
for many water conditions. Additionally, historical data can be
viewed allowing quick and easy troubleshooting. In most cases,
Level I programming is all that is required to set up the water
conditioning system for proper operation. A brief description of
each program level is listed below.
•
Level l: Used to program control for normal applications.
•
Level ll: (P-Values) Allows the installer to customize
programming for non-standard applications.
•
Level lll: (C-Values) Allows the installer to adjust the length
of select cycles for non-standard applications.
•
Level IV: History (H-Values) Allows access to historical
information for troubleshooting the system.
Note: If a button is not pushed for thirty seconds, the control
returns to normal operation mode.
Control Operation
Power Loss Memory Retention
The Analyzer control features battery-free Time of Day and Day of
Week retention during loss of power. A super capacitor is designed
to hold the information in memory for 8 to 24 hours depending on
the installation. If the super capacitor is exhausted, the Analyzer
control will display four dashes (- - :- -) immediately upon power
up. The Time of Day and Day of Week must be reset.
All other programmed parameters are stored in the static memory
and are retained during power outages.
Level I Programming
The Analyzer control can be quickly programmed by following
the sequential procedure on the following page. Level I program
parameters are those that can be accessed by pressing the UP or
DOWN buttons.
• Valve Type: Select 268 for traditional refilling the salt tank
last. Select 268r to have a normally dry salt tank that is
filled when the regeneration cycle starts.
• Resin Volume Setting: Set to match the volume (cubic feet)
of resin in the mineral tank.
• Time of Day: Includes PM indicator. Can be set to display as
a 24-hour clock. See Level ll Programming.
• Day of Week: Set to actual day of the week.
• Time of Regeneration: Fully adjustable. Default is 2:00 AM.
• Days Override: Range 0.5 to 99 days. Leave at 0 to disable.
• Salt Dosage: Set at pounds of salt per cubic foot of resin in
the conditioner tank.
Note: When the control is set up for a twelve-hour clock a PM
indicator will illuminate when the displayed time is in the PM
hours. There is no AM indicator.