Water Filtration System Performance Data Sheet
This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42, 53 and 58 for
the reduction of the substances listed below. The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42,53,58 and 372.
Substance
Arsenic (Pentavalent)
Barium
Radium 226/228
Cadmium
Chromium (Hexavalent)
Chromium (Trivalent)
Lead
Copper
Selenium
TDS
Aesthetic Chlorine
VOC*
While testing was performed under laboratory conditions, actual performance may vary.
General Operating Information:
Rated Capacity
Min-Max operating pressure:
Min-Max feed water temperature:
Rated Service Flow
Daily Water Production Rate
Product Efficiency Rating
Electrical Requirements:
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
• Refer to the owners manual for specific installation instructions, manufacturer's limited warranty, user
responsibility, and parts and service availability.
• The influent water to the system shall include the following characteristics:
o
No organic solvents
o
Chlorine: < 2 mg/L
o
pH: 7 - 8
o
Temperature: 41 ~ 95 ºF (5 ~ 35 ºC)
o
Iron: < 2 mg/L
o
Turbidity: < 1 NTU
o
Hardness: < 1 000 mg/L
Influent Challenge Concentration
(mg/L unless specified)
0.050 ± 10%
10.0 ± 10%
25 pCi/L
0.03 ± 10%
0.3 ± 10%
0.3 ± 10%
0.15 ± 10%
3.0 ± 10%
0.10 ± 10%
750 ± 40
2.0 ± 10%
0.300 ± 10%
Model: CHP-590L
Maximum Allowable Product Water
Concentration
(mg/L unless specified)
0.010
2.0
5 pCi/L
0.005
0.1
0.1
0.010
1.3
0.05
187
≥ 50% reduction
≥ 95% reduction
290 gallons (for VOC)
5 000 gallons (for Aesthetic Chlorine)
20 ~ 120 psi (1.4 ~ 8.4 kgf/cm
41 ~ 95 ºF (5 ~ 35 ºC)
0.07 GPM
67.6 GPD
31.8 %
Refer to the rating plate.
Percent Reduction
(%)
97.8
97.3
80
98.4
98.6
99.4
99.3
98
98.4
92.4
72.8
99.8