THE 'VENT' INDICATOR
When there is insufficient ventilation, the heater shuts off automatically. When this
occurs, e -1 1 is displayed and the
is lit (Fig. K). After improving the ventilation of the room (e.g. by opening a door or
window a little more), the heater can be ignited by pushing
N
MAINTENANCE
Switch off the heater and let it cool down, before you start any maintenance
work. Also disconnect the plug from the mains. Your heater needs hardly any
maintenance. It is, however, important that you clean the air filter
vent filter
with a vacuum cleaner and the grid · with a damp cloth, both on
a weekly basis. Remove the air filter cap occasionally (Fig. L) and clean it with
soapy water. Prior to reinstallation, make sure that the air filter cap has fully dried.
Regularly inspect the fuel filter as well:
1 Remove the removable tank
(Fig. M). Some drops may leak from the filter; keep a cloth at hand.
2 Remove the dirt by tapping the fuel filter upside-down against a hard surface.
(Never clean it with water!)
3 Reinstall the fuel filter into the heater.
We recommend that you remove dust and stains from time to time with a damp
cloth, because otherwise these may cause stains that are hard to remove.
!
Do not remove any heater components yourself. Always contact your dealer
for repairs. When the power cord is damaged, it may only be replaced by an
authorised fitter. Use a new cord of the type H05 VV-F.
O
STORAGE (END OF THE HEATING SEASON)
At the end of the heating season, you must store the heater in a dust-free place, if
possible in its original packaging. Unused fuel cannot be used in the next heating
season. We therefore recommend that you burn up all fuel. If there is still some
fuel left, do not throw it away, but dispose of it in accordance with the local
regulations for the disposal of domestic chemical waste.
Always start the new heating season with fresh fuel. When you start re-using the
heater follow the instructions again (starting from Section A and as specified).
4
12
indicator is blinking and VENT indicator ( )
¹ again.
from the heater and remove the fuel filter
K: A blinking
indicator is a sign
that you need extra
ventilation.
and the
Fuel filter