Using the test probes, touch the test points of the test object. The multimeter automatically searches for the most suitable
measurement range.
Read measurement value on the display.
DIODE:
Set the selector switch to measurement range 'Ω'.
Insert the black test lead into the 'COM' socket and the red test lead into the right-hand socket.
Use the 'M' button to set the device to
. Using the test probes, touch the test points of the test object. Red test lead = anode
Black test lead = cathode.
The forward voltage drop is displayed.
CONTINUITY TEST:
Set the selector switch to measurement range 'Ω'.
Insert the black test lead into the 'COM' socket and the red test lead into the right-hand socket.
Using the button 'M', set the device to ' )) '. Using the test probes, touch the test points of the test circuit. An acoustic signal is
emitted if resistance below 50 Ω is measured. Read measurement value on the display.
Important: Isolate from the power supply and discharge capacitors in the circuit to be measured.
5. Changing the battery/fuse
Change the battery when the battery symbol is displayed. Remove the test leads from the measuring instrument before changing
the battery or fuse!
Use the specified batteries/fuses only!
Rear of instrument
Remove the screw on the rear of the instrument, open the battery compartment and remove the used batteries.
Important: Do not dispose of batteries in normal household rubbish!
Observe statutory regulations pertaining to disposal!
Insert new batteries (2 x 1.5 V AAA Micro). Replace battery compartment cover and screw tight.
When changing the fuse, always remove the test leads from the instrument and undo all screws on the rear; carefully remove the
rear of the housing and replace the fuses with fuses of the same type. Fuse: F 200 mA or 10 A/690 V
Replace screws and screw tight.
6. 60 months warranty
®
WAGO
instruments are subject to strict quality controls. The instrument is covered by a warranty for a period of 60 months against
the functions developing faults during the course your daily work (valid only with invoice). We will rectify production or material
defects free of charge upon return if these have not been caused by misuse or abuse. Damage resulting from a fall or improper
handling is excluded from the warranty. Should faults affecting the functioning of the device occur once the warranty has elapsed,
our technical service will carry out the necessary repairs without delay. Please contact:
This operation manual has been created with due care and attention. No claim is made nor a guarantee given that the data,
illustrations and drawings are complete or correct. Subject to change without notice
WAGO Kontakttechnik GmbH & Co. KG
Postfach 28 80 · 32385 Minden
Hansastraße 27 · 32423 Minden
Tel.:0049(0)571/887-0
FAX.:0049(0)571/887-169
info@wago.com
www.wago.com
- 12 -