DIODE Test:
RANGE
RESOLUTION
0.001 V
Forward biasing current: approx. 0.6 mA, backward voltage: approx. 1.5 V,
Over-range protection: 600 V AC/DC < 30s
CONTINUITY TEST:
RANGE
◦))
Measuring-circuit voltage: approx. 0.5 V, over-range protection: 600 V AC/DC < 30s

4. Application description

DC VOLTAGE MEASUREMENT
Set the selector switch to measurement range V=.
Insert the black test lead into the 'COM' socket and the red test lead into the right-hand socket. Using the test probes, touch the test
points of the test object.
The multimeter automatically searches for the most suitable measurement range. Read measurement value on the display.
AC VOLTAGE MEASUREMENT (contact or non-contact techniques)
Set the selector switch to measurement range V~.
Insert the black test lead into the 'COM' socket and the red test lead into the right-hand socket. Using the test probes, touch the test
points of the test object.
The multimeter automatically searches for the most suitable measurement range. Read measurement value on the display.
The display blinks and an acoustic signal is emitted when, with the M-button held pressed down, the top edge of the multimeter is
held up to a live conductor (100 - 600 V AC). The instrument functions in the same manner during a single-pole phase test using
the red test lead.
DC CURRENT MEASUREMENT:
Set the selector switch to measurement range A.
Use the 'M' button to set the device to DC.
Insert the black test lead into the 'COM' socket and the red test lead into the right-hand socket (up to max. 200 mA).
You must use the '10 A' socket when measuring currents above 200 mA.
Using the test probes, touch the test points of the test object.
The multimeter automatically searches for the most suitable measurement range.
Read measurement value on the display.
AC CURRENT MEASUREMENT:
Set the selector switch to measurement range A.
Use the 'M' button to set the device to AC.
Insert the black test lead into the 'COM' socket and the red test lead into the right-hand socket (up to max. 200 mA).
You must use the '10 A' socket when measuring currents above 200 mA.
Using the test probes, touch the test points of the test object.
The multimeter automatically searches for the most suitable measurement range. Read measurement value on the display.
RESISTANCE MEASUREMENT:
Set the selector switch to measurement range 'Ω'.
Insert the black test lead into the 'COM' socket and the red test lead into the 'INPUT' socket.
FUNKTION
Displays the
forward voltage drop
FUNKTION
The integrated buzzer signals
signals continuity up to 50 Ω