Note: Troubleshooting problems may have similar causes and solutions.
PROBLEM
Low discharge pressure
Excessive unloader cycling Fittings leak
Air leaks from regulator, or
regulator does not regulate
pressure
Regulated pressure gauge
reading drops when air
accessory is being used.
Compressor won't start in
cold temperatures
Overheating
200-3155
TROUBLESHOOTING
POSSIBLE CAUSE
Tank petcock is open
Fittings Leak
Restricted air intake
Restricted check valve
Hole in air hose
Tank leaks
Blown seals
Valve leaks
Leaking or worn piston seal
Dirty or damaged regulator
internal parts.
This is normal
Compressor not large enough
Engine flooded
Compressor too cold
Poor ventilation
Dirty cooling surfaces
Leaking valve
SOLUTION
Close petcock
Check fittings with soapy water. Tighten or reseal leaking fittings.
DO NOT OVERTIGHTEN.
Clean or replace air filter element.
Remove and clean or replace.
Check and replace if necessary
Immediately replace tank. DO NOT attempt to repair.
Replace any faulty seals
Replace worn parts and reassemble with new seals.
Replace piston and cylinder sleeve assemblies.
Check fittings with soapy water. Tighten or reseal leaking fittings.
DO NOT OVERTIGHTEN.
Clean or replace regulator or internal parts.
If pressure drops too low, adjust regulator while accessory is used.
Check air requirement of accessory. If it is higher than CFM and
pressure supplied by compressor, you need a larger compressor.
Most accessories are rated at a 25% duty cycle.
Remove spark plug and dry it. Reinstall.
Move compressor to a warmer location.
Relocate compressor to an area with cool, dry and well-circulated
air.
Clean all cooling surfaces of pump and engine thoroughly.
Replace worn parts and reassemble with new seals.
7 - ENG