System Setup (continued)
9
Connect power supply cord to nearest outlet.
10
Set resin volume.
• When the system is first plugged in, the display indicator
will point to Resin.
• Hold the Up button to begin programming.
• Use the Up or Down arrow to select the amount of
resin in your tank using the chart below to find the
correct setting. Resin range is 0.25-4.0 cu. ft. Do not
use the F setting as it is reserved for filter systems only.
• Hold the Extra Cycle button for five seconds to save the
resin volume.
Mode Button
Model
Resin Volume
NOTE: The resin volume setting will only be displayed at first power-up
or when the user manually advances the Mode button to Resin.
NOTE: Press the Mode button to cycle through programming options.
The display indicator will point to each mode as you navigate through
the settings.
Time of
Day
Time of
Regen
Salt
Amount
MODE
Down Arrow
Up Arrow
PS3000M
PS3500M
0.75 cu. ft.
1.0 cu. ft.
Hardness
PM
Capacity
Remaining
Resin
Extra Cycle
Button
PS3700M
PS3900M
1.5 cu. ft.
2.5 cu. ft.