Instructions for use Rotaplex Visign RT3 / RT5
GB
D
Pipe interrupter
Safeguard drinking water from contamination.
The drinking water quality must not be affected by bath water flowing back into the
drinking water system. To prevent contamination, a pipe interrupter must be installed
between the concealed shut-off fitting and the bathtub inlet. Local standards and regu-
lations must be observed.
Note: The pipe interrupter is not included in the scope of delivery and must be ordered
separately!
 Backflow situation:
If an underpressure situ-
ation should occur when
the bathtub is filled,
there is a risk that water
from the tub will flow
back into the drinking
water system.
E
Assembly steps
 Mount seal. With steel
bathtubs with wall thick-
ness d
max
both seals.
 Insert double seal.
 Bowden wire length
725mm:
Mount overflow pipe. If
necessary, shorten. The
overflow pipe must be
inserted at least 15 mm
into the connection.
 Installation diagram
 Push the inlet piece into
≤ 3 mm mount
 Attach the stainless
 Bowden wire length
the overflow unit.
steel flange to the drain
fitting using the fastening
screws.
1070 mm:
Mount overflow pipe. If
necessary, shorten. The
overflow pipe must be
inserted at least 15 mm
into the connection.
31
 Connecting set with
concealed pipe inter-
rupter DN 20 in acc.
DIN EN 1717 DB
model 6161.86
 Screw the fastening
screws in hand tight.
Caution: On the
hexagon of the fastening
aid (included in the
scope of delivery), there
is a groove, which must
be positioned on the lip
of the fastening screw.
 Push the rubber sleeve
onto the overflow pipe
until the lower edge is
flush with the edge of
the overflow pipe.
 Bowden wire length
725mm, 1070mm:
Push the top end of the
overflow pipe into the
sleeve.
Push the union nut,
sliding ring and wedge
seal onto the overflow
pipes and screw tight.