Gas Heater Hook-Up - Cal Spas Avalon Serie Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 51

Gas Heater Hook-up

Ultimate Fitness Series spa owners may buy and install a separate gas heater and pump for use with their spa.
This option may be purchased separately from your local distributor.
Spa owners are responsible for ensuring installation of their gas heater conforms to local, state, and federal
regulations. The electrical and gas installation must be performed by contractors and approved by a local
building / electrical inspector. Failure to do so may void your warranty.
All Ultimate Fitness Series spas are plumbed with a gas heater ready union located inside the cabinet at either
the front or rear, depending on the model. (See the figures below and on the next page.) Properly installed,
they can be attached to an external gas heater. Customers are responsible for creating openings in the panel
to accommodate the lines and wiring. The gas heater should be located not less than 3m and no more than
7.6m away from the spa.
To connect the plumbing for an external gas heater:
1.
Disconnect the ready union.
2.
Cut off both sides of the union and discard it.
3.
Create two 6.35 cm diameter holes through the spa panel.
4.
Use two 5 cm (2") couplings to connect the hoses to 3m - 4.5m 5 cm (2-3/8") diameter PVC lines.
5.
Connect PVC lines to the gas heater.
2010 Portable Spa
LTR20101001, Rev. B
9
www.calspas.com