Page 1
G24 SERIES GAS COUNTER EQUIPMENT & G20 SERIES STOCK POT RANGES Installation, Operation and Maintenance Manual This manual is updated as new information and models are released. Visit our website for the latest manual. Model G20-SP (stock pot not included)
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
• Many local codes exist, and it is the responsibility of the Owner and the Installer to comply with those codes. • Garland reserves the right to change or improve our specifi cations without notifi cation. • These appliances are intended for commercial use by professionally trained personnel.
This product must be installed by professional personnel as specifi ed. Garland/U.S. Range products are not approved or The rating plate is visible by removing the lower front panel authorized for home or residential use, but are intended for on the G22 Series, the drip tray on the G24 Series or the valve commercial applications only.
INSTALLATION continued Clearances 3. Have a qualifi ed gas technician check the gas pressure to make certain that existing gas facilities (meter, piping, etc.) will deliver the BTU’s of gas required at the unit with Minimum Installation Clearances To Adjacent no more than 1/2”...
INSTALLATION continued Leg Installation 1. Level each unit by adjusting leveling bolts or legs. Use a spirit level and level unit four ways; across front and back G24 Series and down left and right edges. Level all other units to the fi rst unit, securing each unit to the adjacent unit.
OPERATION Hot Plate – Model G24-15H 5. Replace dial and turn to “OFF” position. Calibration Instructions Pilot Burner Adjustment 1. Use a test instrument with a special disc type 1. Remove ring grates and top grate, if not already removed. thermocouple or a reliable surface type pyrometer.
OPERATION continued G20-SPH Stock Pot Range Lighting Standing Pilots - All Models This stock pot range is equipped with an automatic safety These units are not designed to be disconnected from pilot system. Should the pilot go out, the main burner gas their gas connections and re-installed on a regular basis.
FLAME SIZE CHART – ALL MODELS The correct air and/or gas adjustment has been made when a stable blue inner cone is obtained. (Refer to chart for fl ame size.) MODEL BURNER FLAME LENGTH - NORMAL DESCRIPTION PILOT FLAME LENGTH PRESSURE - VALVE OR THERMOSTAT SERIES FULL OPEN...
CLEANING AND MAINTENANCE continued Top Sections Open Top Griddle Top Porcelain Tops & Grates – Top grates should be washed daily with a hot detergent or soap solution and dried thoroughly. Seasoning – Before being used for the fi rst time, all griddle surfaces must be seasoned.
Page 12
GARLAND 1177 KAMATO ROAD, MISSISSAUGA, ONTARIO, CANADA, L4W1X4 888-442-7526 WWW.GARLAND-GROUP.COM Every new piece of Manitowoc Foodservice equipment comes with KitchenCare™ and you choose the level of service that meets your operational needs from one restaurant to multiple locations. StarCare – Warranty & lifetime service, certifi ed OEM parts, global parts inventory, performance audited ExtraCare —...