Connected unit No. table (SW3)
Switch No.
6
7
8
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
SW4 switch setting (Both switches are factory-preset to ON position.)
Switch No.
BGM broadcast volume attenuation*
1
2
No attenuation
OFF
OFF
–28 dB (just audible)
ON
ON
Don't care
–
* Determines the attenuation level when the broadcast of higher priority (level 2 or 3) overrides the BGM
broadcast (priority level 4). (For details, see
instruction manual supplied with the VM-2120 or VM-2240.)
USE OF VR COVERS
The VM-2120/-2240 has 4 VR covers attached as accessories. They are prepared as security covers for the
setting of volume and tone controls. Remove the knob of volume or tone control and put the VR cover instead
of it.
If you need more VR covers, they are available as spare parts.
No. of Connected Units*
0
1
2
3
4
5
∞
dB (inaudible)
* The total number of one Sub-VM amplifier and up to 4
Remote Microphones (excluding the Master amplifier
and Remote Microphone Extension)
p. 26 "GENERAL-PURPOSE BROADCAST PRIORITY" of the
11