6 - MAINTENANCE AND STORAGE

Before working on the pump, unplug it.
In the event of an obstruction, unscrew the reversible
base (I, fig.4) to access the suction chamber, rinse it
Incidents
A - The pump will
not start.
b- The pump is
running but will
not flow, or flow is
reduced
c- The pump
stops during the
operation (the
thermal circuit
breaker has
stopped the pump
after it over-
heated).
For any other anomaly, contact our after-sales service. For safety reasons, only the Hozelock-Exel after-sales
service is entitled to disassemble the pump.
7 - OPERATING ANOMALIES / SOLUTIONS
Causes
1- The water level has not reached
the trigger level of the pump.
2- No power supply.
3- Dirt is stuck in the housing of the
turbine.
1- Dirt is stuck in the housing of the
turbine.
2- The discharge hose is blocked.
3- A pocket of air has occurred:
- Because of the float setting, the
stop level is too low, so the pump
sucks in air.
- When diving the device.
1- The power supply is not consis-
tent with the motor data of the pump.
2- A solid body has blocked the
hydraulic system.
3- The pump worked with too hot
water.
4- The pump has worked dry.
5 - The pump has worked too long
without interruption.
with clean water and reassemble. In the dirty water
position, also check that nothing is blocking the drain
hose.
Do not let the pump freeze.
1- Ability to adjust the switch (B) to adjust
the trigger level of the pump.
2- Check that the plug is well inserted into
the socket. Check the circuit breakers and
electrical connections outside the pump.
Check the condition of the cables.
3- Disconnect the pump, disassemble the
reversible base and clean the suction cham-
ber.
1- Disconnect the pump, disassemble the
reversible base and clean the suction cham-
ber.
2- Remove the discharge hose and unblock
it.
3 - Adjust the float, so that the stop level is
above the level of the turbine.
- Open the discharge hose (or remove
anything that is blocking the air outlet), then
immerse the pump by tilting and shaking it.
- Check that the water level is sufficient to
start aspiration.
Disconnect the pump, remove any blockage,
wait for the pump to cool down and connect
it again.
8
GB
Solutions