Storage temperature:
Humidity:
Pressure/Altitude:
PHYSICAL CHARACTERISTICS
Acoustic Noise:
Water resistance class:
Cooling:
Dimensions:
European Standards:
Casing material:
Treatment:
Standard colour:
Weight:
Number of charging points:
Cable length:
Maximum cable thickness:
MTBF:
DC power plug:
Enclosure protection against external
impacts:
Loadbalancer:
CONTROL
Back office protocol :
Start-Stop:
Suitable charge cards:
Network interface:
Push button:
Pay attention ! Earthing (earth dispersion resistance) completely
26. www.ecotap.nl
in accordance with the applicable standards.
- 40°C ~ 85°C
≤ 95% RH, without condensation
79kPa~106kPa/2000m
< 62dB
IP54
Air Cooling fans
1440 mm x 610 mm x 350 mm
EN 61851-1 2011, EN 6185123-2014, CE
Steel >3 mm
Anti-corrosion and powder coating
Body: RAL 6018 / Cover: RAL 9016
235 kg
2 (Combination from CCS and CHADEMO)
3 meter
50 mm2
> 500000 hrs (40°C)
Mode 4 (IEC-61851-23/24) Combo-2 (DIN
10121)
> IK10 according to IEC 62262
Charging speed is adjusted based on the
available amount of energy at a certain
moment within the network connection.
OCPP 1.6 Json
RFID-card
Mifare, NTag and iCODE SLI cards
(
more info
)
Ethernet (standard) / GPRS-UMTS (4G)
Emergency stop button
20-04-22